Suppr超能文献

采用韩国分离株对 VITEK MS 鉴定临床相关丝状真菌广谱性能的评估。

Performance Evaluation of VITEK MS for the Identification of a Wide Spectrum of Clinically Relevant Filamentous Fungi Using a Korean Collection.

机构信息

Department of Laboratory Medicine, Chonnam National University Medical School and Chonnam National University Hwasun Hospital, Hwasun, Korea.

Department of Microbiology, Chonnam National University Medical School, Hwasun, Korea.

出版信息

Ann Lab Med. 2021 Mar 1;41(2):214-220. doi: 10.3343/alm.2021.41.2.214.

Abstract

The correct identification of filamentous fungi is challenging. We evaluated the performance of the VITEK MS v3.0 system (bioMérieux, Marcy-l'Étoile, France) for the identification of a wide spectrum of clinically relevant filamentous fungi using a Korean collection. Strains that were added to the upgraded v3.2 database were additionally identified by the VITEK MS v3.2 system. Of the 105 tested isolates, including 37 (nine species), 41 dermatophytes (seven species), and 27 other molds (17 species), 43 (41.0%) showed "no identification" or "multiple species identification" results at the initial VITEK MS testing; these isolates were retested using the same method. Compared with sequence-based identification, the correct identification rate using VITEK MS for , dermatophytes, other molds, and total mold isolates was 67.6%, 56.1%, 48.1%, and 58.1% at the initial testing and 94.6%, 78.0%, 55.6%, and 78.1% with retesting, respectively. Following retesting, 19 (18.1%) and two (1.9%) isolates showed "no identification" and "misidentification" results, respectively. VITEK MS reliably identified various filamentous fungi recovered in Korea, with a very low rate of misidentification.

摘要

丝状真菌的正确鉴定具有挑战性。我们使用韩国的真菌分离株评估了 VITEK MS v3.0 系统(bioMérieux,法国马西-埃托勒)鉴定广泛临床相关丝状真菌的性能。添加到升级的 v3.2 数据库中的菌株还通过 VITEK MS v3.2 系统进行了鉴定。在 105 株测试分离株中,包括 37 株(9 种)、41 株皮肤癣菌(7 种)和 27 株其他霉菌(17 种),43 株(41.0%)在初始 VITEK MS 检测中显示“无法鉴定”或“多种物种鉴定”结果;这些分离株用相同的方法进行了重新测试。与基于序列的鉴定相比,VITEK MS 对 、皮肤癣菌、其他霉菌和总霉菌分离株的正确鉴定率在初始测试时分别为 67.6%、56.1%、48.1%和 58.1%,在重新测试时分别为 94.6%、78.0%、55.6%和 78.1%。重新测试后,分别有 19 株(18.1%)和 2 株(1.9%)分离株显示“无法鉴定”和“误鉴定”结果。VITEK MS 可可靠地鉴定韩国分离出的各种丝状真菌,误鉴定率非常低。

相似文献

8
Vitek MS v3.0 System in the Identification of Filamentous Fungi.Vitek MS v3.0 系统在丝状真菌鉴定中的应用。
Mycopathologia. 2019 Oct;184(5):645-651. doi: 10.1007/s11046-019-00377-0. Epub 2019 Sep 10.

引用本文的文献

本文引用的文献

1
Molecular diagnostics in medical mycology.医学真菌学中的分子诊断。
Nat Commun. 2018 Dec 3;9(1):5135. doi: 10.1038/s41467-018-07556-5.
6
Emerging issues, challenges, and changing epidemiology of fungal disease outbreaks.真菌病暴发的新出现问题、挑战及流行病学变化
Lancet Infect Dis. 2017 Dec;17(12):e403-e411. doi: 10.1016/S1473-3099(17)30443-7. Epub 2017 Jul 31.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验