土耳其阻塞性睡眠呼吸暂停患者医学结局研究(MOS)睡眠量表的信度和效度研究。

Turkish reliability and validity study of the medical outcomes study (MOS) sleep scale in patients with obstructive sleep apnea.

机构信息

Department of Mental Health and Diseases, Sleep Research Center, Gülhane Education and Research Hospital, Ankara, Turkey

Department of Military Health Services, Ministry of National Defense, Ankara, Turkey

出版信息

Turk J Med Sci. 2021 Feb 26;51(1):268-279. doi: 10.3906/sag-1909-157.

Abstract

BACKGROUND/AIM: The purpose of the present study was to evaluate the Turkish reliability and validity of the medical outcomes study (MOS) sleep scale in patients who have obstructive sleep apnea.

MATERIALS AND METHODS

The data of the study were collected from 120 adult patients with obstructive sleep apnea and from 90 healthy individuals between March 04 and May 31, 2019.

RESULTS

The Cronbach’s α internal consistency reliability coefficient of the MOS sleep scale was found as 0.82. The test-retest reliability was acceptable (r = 0.76-0.94). Six factors were identified by the factor analysis. These were the same as those in the original MOS-Sleep. The correlations between the MOS-Sleep and other instruments administered in this study provided evidence for structural validity. A significant relation was determined between MOS sleep scale and obstructive sleep apnea syndrome (OSAS) severity and the healthy group ( P < 0.05). In addition, the Cronbach α internal consistency reliability coefficient of the healthy group in MOS sleep scale was found as 0.78. The items of the six factors that were obtained with the confirmatory factor analysis for the MOS sleep scale of the healthy group were found to be the same as in the original MOS-Sleep.

CONCLUSION

Turkish MOS sleep scale is a measurement tool that consists of 12 items and 6 subdimensions with adequate validity and reliability indicators.

摘要

背景/目的:本研究旨在评估 MOS 睡眠量表在阻塞性睡眠呼吸暂停患者中的土耳其信度和效度。

材料与方法

本研究的数据于 2019 年 3 月 4 日至 5 月 31 日期间从 120 名成年阻塞性睡眠呼吸暂停患者和 90 名健康个体中收集。

结果

MOS 睡眠量表的 Cronbach's α 内部一致性信度系数为 0.82。重测信度可接受(r = 0.76-0.94)。通过因子分析确定了 6 个因素。这些因素与原始 MOS-Sleep 中的因素相同。MOS-Sleep 与本研究中其他仪器的相关性为结构效度提供了证据。MOS 睡眠量表与阻塞性睡眠呼吸暂停综合征(OSAS)严重程度和健康组之间存在显著关系(P < 0.05)。此外,MOS 睡眠量表中健康组的 Cronbach α 内部一致性信度系数为 0.78。用验证性因子分析获得的 MOS 睡眠量表的 6 个因子的项目与原始 MOS-Sleep 中的项目相同。

结论

土耳其 MOS 睡眠量表是一种由 12 个项目和 6 个亚维度组成的测量工具,具有足够的有效性和可靠性指标。