Department of Physiotherapy, Faculty of Medicine and Health Sciences, Universitat Internacional de Catalunya, UIC Barcelona, Sant Cugat del Vallès, 08195 Barcelona, Spain.
Fundació Institut Universitari per a la recerca a l'Atenció Primària de Salut Jordi Gol i Gurina (IDIAPJGol), 08007 Barcelona, Spain.
Int J Environ Res Public Health. 2020 Oct 22;17(21):7733. doi: 10.3390/ijerph17217733.
A force platform must have validity and reliability for optimal use. The objective of this study was to analyze the validity and the reliability of the Satel 40 Hz stabilometric force platform.
A study of instrumental validity and reliability, involving a cross-sectional correlational and comparative analysis was performed. To determine the validity, four certified weights located on three axes were used and the ability of the stabilometric force platform to detect changes in the position of the different axes was observed. A test-retest was performed to analyze the reliability. Forty-two symptom-free volunteers participated in the study. Assessments were taken in a standing static position and in a dynamic position, with the eyes open and closed. Three measurements were taken and the intra-class correlation coefficient (ICC) was calculated.
The validity increased as the weight increased for all the variables measured in the stabilometric parameters ( < 0.05). The reliability was shown to be good to excellent for the two visual conditions. The positional variables obtained a higher ICC. The variable with the best ICC was the Y mean in OE (ICC 0.874 and a < 0.001). All the values showed an increase in a dynamic situation.
The findings support the reliability and validity of the Satel 40 Hz stabilometric force platform. The platform could be recommended to evaluate static and dynamic standing balance in healthy adult individuals. Guidelines for treatment and the level of quality of stabilometry could be obtained from its use.
力台必须具有有效性和可靠性才能达到最佳使用效果。本研究的目的是分析 Satel 40Hz 平衡测力台的有效性和可靠性。
进行了一项仪器有效性和可靠性的研究,涉及横向相关和比较分析。为了确定有效性,使用了位于三个轴上的四个经过认证的砝码,并观察了平衡测力台检测不同轴位置变化的能力。进行了测试-再测试以分析可靠性。42 名无症状志愿者参加了这项研究。在站立静态位置和动态位置、睁眼和闭眼时进行评估。进行了三次测量,并计算了组内相关系数(ICC)。
在所有平衡参数的测量中,随着重量的增加,有效性都有所提高(<0.05)。在两种视觉条件下,可靠性被证明是良好到极好的。位置变量的 ICC 更高。OE 中 Y 均值的 ICC 最好(ICC 0.874,<0.001)。所有值在动态情况下都有所增加。
研究结果支持 Satel 40Hz 平衡测力台的可靠性和有效性。该平台可用于评估健康成年人的静态和动态站立平衡。可以从其使用中获得治疗和稳定计质量水平的指导方针。