• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Chemiluminescence immunoassay of thyrotropin with acridinium-ester-labeled antibody evaluated and compared with two other immunoassays.

作者信息

Bounaud M P, Bounaud J Y, Bouin-Pineau M H, Orget L, Begon F

机构信息

Laboratoire de Biophysique Cellulaire, Hôpital Jean Bernard, Poitiers, France.

出版信息

Clin Chem. 1987 Nov;33(11):2096-100.

PMID:3315305
Abstract

A new chemiluminometric immunoassay of thyrotropin (TSH) involves antibody labeled with acridinium ester ("Magic Lite System," Ciba Corning Diagnostic Corp.). The assay is rapid, with two incubations totaling 2.5 h, requires two standards per run, and takes 10 s per sample for the quantification step. Analytical performance, within- and between-run reproducibilities, and linearity were excellent. The detection limit is 0.04 milli-int. unit/L. Results correlated well with those obtained by immunoradiometric assay (RIA-gnost hTSH, Hoechst-Behring) and immunofluorometric assay (hTSH Delfia, LKB): r = 0.975. TSH measurements in 32 euthyroid subjects ranged from 0.4 to 4.8 milli-int. units/L (mean 1.35 milli-int. units/L). TSH values for 51 hypothyroid and subclinically hypothyroid patients ranged from 2 to 65 milli-int. units/L. TSH values for 33 hyperthyroid patients (less than 0.14 milli-int. unit/L, less than 0.04 milli-int. unit/L in 16 of the 33) were clearly lower than for most untreated euthyroid subjects. For 169 other individuals whose thyroid function was being routinely assessed. TSH ranged from 0.4 to 4.8 milli-int. units/L, three had TSH less than 0.14 milli-int. unit/L, and four had TSH between 0.14 and 0.4 milli-int. unit/L. This system is as efficient and reliable for screening for thyroid function as the two comparison systems.

摘要

相似文献

1
Chemiluminescence immunoassay of thyrotropin with acridinium-ester-labeled antibody evaluated and compared with two other immunoassays.
Clin Chem. 1987 Nov;33(11):2096-100.
2
A sensitive and practical immunoradiometric assay of thyrotropin.一种灵敏且实用的促甲状腺激素免疫放射测定法。
Clin Chem. 1986 Mar;32(3):514-8.
3
Enhanced luminescence immunoassay: evaluation of a new, more sensitive thyrotropin assay.
Clin Chem. 1986 Dec;32(12):2178-83.
4
An automated immunoradiometric assay for human thyrotropin.人促甲状腺素的自动化免疫放射分析
Clin Chem. 1984 Aug;30(8):1396-8.
5
Determination of thyrotropin in serum by time-resolved fluoroimmunoassay evaluated.
Clin Chem. 1985 Oct;31(10):1706-9.
6
Clinical application of a sensitive non-isotopic immunometric assay of thyrotropin.
Clin Chem. 1987 Jan;33(1):179-81.
7
Thyrotropin as measured by a sensitive immunoradiometric assay.采用灵敏的免疫放射分析测定促甲状腺激素。
Clin Chem. 1985 Nov;31(11):1865-7.
8
Immunoenzymatic quantification of low concentrations of thyrotropin.低浓度促甲状腺激素的免疫酶定量分析
Clin Chem. 1987 Jul;33(7):1223-6.
9
Methodological evaluation of a new chemiluminescence immunoassay for thyrotropin using acridinium ester-labelled antibody.使用吖啶酯标记抗体的促甲状腺激素新型化学发光免疫分析方法学评价
J Biolumin Chemilumin. 1989 Jul;4(1):620-6. doi: 10.1002/bio.1170040182.
10
"Delfia" and "Amerlite": two sensitive nonisotopic immunoassay systems for assay of thyrotropin compared.“德尔菲亚”和“美诺利特”:两种用于促甲状腺激素检测的灵敏非同位素免疫分析系统的比较。
Clin Chem. 1987 Aug;33(8):1421-4.