对通过计算机辅助设计/计算机辅助制造(CAD/CAM)铣削制作的铬钴合金与钛合金框架种植体的适合性分析。

Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

作者信息

Oteiza-Galdón Begoña, Martínez-González Amparo, Escuder Ángel-Vicente

机构信息

Faculty of Dentistry, European University of Valencia, Spain.

Polytechnic University of Valencia.

出版信息

J Clin Exp Dent. 2020 Oct 1;12(10):e951-e957. doi: 10.4317/jced.57817. eCollection 2020 Oct.

Abstract

BACKGROUND

This study analyzed the degree of passive and vertical fit achieved in frameworks using either cobalt-chromium (Co-Cr) or titanium (Ti) implant-supported fixed partial dentures ( FPDs) fabricated with a CAD/CAM milling technique.

MATERIAL AND METHODS

33 3-unit FDPs, 17 of Co-Cr metal alloy (test group) and 16 of Ti (control group), were manufactured with two implants by copy milled technology. Optical microscopy was used to measure passive fit (PF) and vertical fit (VF) in all frameworks. The PF was evaluated by using the Single Screw test and the VF with the screws tightened at 20 Ncm. Descriptive and inferential analysis were performed to evaluate statistically significant differences in the tested groups for each fit. Brunner-Langer models were applied to assess potential material and implant area effects on the measurements. An ANOVA test was performed to estimate both main effects and interactions.

RESULTS

The average PF values in the screwed implant were 4.43 ± 0.52 µm for Ti and 5.50 ± 1.61 µm for Co-Cr and in the non-screwed implant 5.59 ± 1.32 µm in the group Ti and 6.25 ± 1.55 µm the Co-Cr group. In this last implant, it was not observed statistically significant differences between both types of alloy ( = 0.178) nor between zones. Ti control group exhibited a significantly better VF than Co-Cr ( = 0.046) in the screwed implant but there were no differences in the implant not screwed. The VF in the non-screwed implant was better in lingual than in buccal zone.

CONCLUSIONS

The PF and VF measurements observed in Co-Cr frameworks are clinically acceptable. 3-unit implant supported FPDs made with Co-Cr alloy using milling technique showed similar dimensional accuracy than those obtained with Ti. Cobalt- chromium alloy, misfit, passive fit, vertical fit, milling.

摘要

背景

本研究分析了使用计算机辅助设计/计算机辅助制造(CAD/CAM)铣削技术制作的钴铬(Co-Cr)或钛(Ti)种植体支持的固定局部义齿(FPD)框架中实现的被动适合度和垂直适合度。

材料与方法

采用复制铣削技术,用两颗种植体制作了33个3单位FDP,其中17个为Co-Cr金属合金(试验组),16个为Ti(对照组)。使用光学显微镜测量所有框架的被动适合度(PF)和垂直适合度(VF)。通过单螺钉试验评估PF,在20 Ncm拧紧螺钉的情况下评估VF。进行描述性和推断性分析,以评估各适合度测试组之间的统计学显著差异。应用Brunner-Langer模型评估潜在的材料和种植体区域对测量结果的影响。进行方差分析以估计主效应和相互作用。

结果

在拧入式种植体中,Ti的平均PF值为4.43±0.52 µm,Co-Cr为5.50±1.61 µm;在非拧入式种植体中,Ti组为5.59±1.32 µm,Co-Cr组为6.25±1.55 µm。在最后一种种植体中,两种合金类型之间(P = 0.178)以及不同区域之间均未观察到统计学显著差异。在拧入式种植体中,Ti对照组的VF显著优于Co-Cr(P = 0.046),但在未拧入的种植体中没有差异。非拧入式种植体的舌侧VF优于颊侧。

结论

Co-Cr框架中观察到的PF和VF测量值在临床上是可接受的。采用铣削技术用Co-Cr合金制作的3单位种植体支持的FPD显示出与Ti相似的尺寸精度。钴铬合金、不适合度、被动适合度、垂直适合度、铣削