Sci Rep. 2020 Nov 30;10(1):20880. doi: 10.1038/s41598-020-77920-3.
The study aimed to compare three methods for determining total (TF) and total soluble fluorides (TSF) in 5 child formula dentifrices (CFD) using Inter-method reliability (IMR) statistical approach. The methods were direct acid-hydrolysis (DM), the least-time-consuming method; Modified direct acid-hydrolysis with standard-addition method (MDM), ISO 19448:2018 method; and modified Taves acid-HMDS diffusion analysis (TAD), the claimed gold standard method. A significant difference in the mean difference was observed for all methods at all levels (p < 0.001), except DM and TAD for TF (p = 0.622). A proportional bias was discerned in the agreement distribution between DM and TAD for TF (p < 0.001). The ICC analysis identified significant reliability between all measurements, irrespective of the model, measure, and fluoride type (p < 0.001). For TF and TSF, the IMR between DM and TAD was lower than MDM and TAD for consistency/absolute agreement reliability at single/average measures. The reliability measure for DM and MDM was higher than MDM and TAD for TSF, but was lower than MDM and TAD for TF. The ICC measure for DM-TAD was significantly lower than DM-MDM and MDM-TAD (p < 0.05). The ISO 19448:2018 MDM is a reliable test that can be used as an alternative to TAD/DM for determining TF/TSF in CFD.
本研究旨在采用方法间可靠性(IMR)统计方法比较 5 种儿童配方牙膏(CFD)中总氟(TF)和总可溶氟(TSF)的三种测定方法。方法为直接酸水解法(DM),最省时;改良直接酸水解法加标准添加法(MDM),ISO 19448:2018 方法;改良 Taves 酸-HMDS 扩散分析法(TAD),号称金标准方法。除 DM 和 TAD 测 TF 时(p=0.622)外,所有方法在所有水平上的均值差异均有统计学意义(p<0.001)。DM 和 TAD 测 TF 时,一致性分布中存在比例偏差(p<0.001)。ICC 分析表明,无论模型、测量和氟化物类型如何,所有测量值之间均具有显著可靠性(p<0.001)。对于 TF 和 TSF,DM 和 TAD 之间的 IMR 一致性/绝对一致性可靠性低于 MDM 和 TAD。DM 和 MDM 的可靠性测量值高于 MDM 和 TAD 的 TSF 测量值,但低于 MDM 和 TAD 的 TF 测量值。DM-TAD 的 ICC 测量值明显低于 DM-MDM 和 MDM-TAD(p<0.05)。ISO 19448:2018 MDM 是一种可靠的测试方法,可替代 TAD/DM 用于 CFD 中 TF/TSF 的测定。