Suppr超能文献

基于 LED 的光声系统对肌腱附着点炎的成像。

Imaging of enthesitis by an LED-based photoacoustic system.

机构信息

University of Michigan, Department of Biomedical Engineering, Ann Arbor, Michigan, United States.

University of Michigan, Department of Ophthalmology and Visual Sciences, Ann Arbor, Michigan, United States.

出版信息

J Biomed Opt. 2020 Dec;25(12). doi: 10.1117/1.JBO.25.12.126005.

Abstract

SIGNIFICANCE

One key pathological characteristic of seronegative spondyloarthropathy (SpA) is inflammation at the insertion of tendons and ligaments into the bone (enthesitis).

AIM

We explore the potential of the emerging photoacoustic (PA) imaging in diagnosis of SpA and review its feasibility in detecting SpA-associated Achilles tendon enthesitis.

APPROACH

A light-emitting diode (LED)-based PA and ultrasound combined system was employed. The PA images, both along the long and the short axes of each Achilles tendon insertion region, were acquired at 850-nm wavelength, which is sensitive in depicting increased blood volume (i.e., hyperemia). To assess the hyperemia indicating enthesis inflammation, two parameters were quantified in the imaged tendons, including the average intensity and the density of the color pixels in the pseudo-color PA images. Ten SpA patients, all of which met Assessment of SpA International Society (ASAS) criteria for SpA and were found to have Achilles enthesitis by clinical exam according to a board-certified rheumatologist, were included in the study.

RESULTS

The PA and Doppler ultrasound imaging of Achilles enthesitis resulting from these 10 SpA patients were compared to those from 10 healthy volunteers, leading to statistically significant differences (p  <  0.05) in the applied t-tests.

CONCLUSIONS

This preliminary clinical study suggests that the LED-based PA imaging holds a promise for sensitive and objective assessment of SpA enthesitis in an outpatient setting of the rheumatology clinic.

摘要

意义

血清阴性脊柱关节病(SpA)的一个关键病理学特征是肌腱和韧带插入骨(附着点)处的炎症(附着点炎)。

目的

我们探索新兴的光声(PA)成像在 SpA 诊断中的潜力,并综述其在检测 SpA 相关跟腱附着点炎中的可行性。

方法

采用基于发光二极管(LED)的 PA 和超声联合系统。在 850nm 波长下获得每个跟腱插入区域的长轴和短轴的 PA 图像,该波长在描绘增加的血管容积(即充血)方面具有较高的灵敏度。为了评估指示附着点炎症的充血,在成像的肌腱中量化了两个参数,包括伪彩色 PA 图像中颜色像素的平均强度和密度。

结果

将这 10 例 SpA 患者的跟腱附着点炎的 PA 和多普勒超声成像与 10 例健康志愿者进行比较,经统计学 t 检验得出有显著差异(p<0.05)。

结论

这项初步的临床研究表明,基于 LED 的 PA 成像在风湿病门诊环境中具有敏感和客观评估 SpA 附着点炎的潜力。