Urine fentanyl test strips have been employed to check street drugs for fentanyl and fentanyl analogue contamination, but there is limited evidence for the applicability of fentanyl strips for this purpose. We examined the ability of four commercially-available fentanyl test strips to detect fentanyl and a range of fentanyl analogues currently on the recreational drug market.
Four brands of fentanyl test strips (Rapid Response, One Step, Nal van Minden, and Rapid Self Test) were examined using single-component drug solutions containing fentanyl, 28 fentanyl analogues, four non-fentanyl synthetic opioids, or eight traditional drugs of abuse. The effect of co-presence of heroin or ascorbic acid on test results was also examined.
All test strips detected fentanyl as well as 21-24 of the 28 fentanyl analogues tested. One of the test strip brands gave false positive results in the presence of ascorbic acid.
Fentanyl test strips successfully detected the majority of fentanyl analogues tested. Drug solutions for testing should not be overly dilute, since the test results are highly concentration dependent. Fentanyl test strips have utility as a harm reduction tool, but they are no panacea for overdose since certain fentanyl analogues are not detected.
尿液芬太尼检测条已被用于检测街头毒品中的芬太尼和芬太尼类似物污染,但对于这些检测条在该用途上的适用性,证据有限。我们研究了四种市售芬太尼检测条检测芬太尼和当前娱乐性毒品市场上一系列芬太尼类似物的能力。
使用含有芬太尼、28 种芬太尼类似物、4 种非芬太尼合成阿片类药物或 8 种传统滥用药物的单一组分药物溶液,对四种品牌的芬太尼检测条(快速反应、一步、Nal van Minden 和快速自我测试)进行了检查。还检查了海洛因或抗坏血酸共存对检测结果的影响。
所有检测条均能检测到芬太尼以及 28 种芬太尼类似物中的 21-24 种。一种检测条品牌在抗坏血酸存在的情况下给出了假阳性结果。