应用 Topcon 仪器的非接触镜面反射显微镜评估健康人眼角膜中央厚度 - 20 年回顾。

Non-contact specular microscopy with Topcon instruments to assess central corneal thickness of healthy human eyes - A 20 year review.

机构信息

Glasgow-Caledonian University, Dept Vis Sci, Glasgow, G4 OBA, United Kingdom.

出版信息

Cont Lens Anterior Eye. 2021 Aug;44(4):101385. doi: 10.1016/j.clae.2020.11.005. Epub 2020 Dec 16.

Abstract

BACKGROUND

The purpose of this review was to evaluate the consistency of central corneal thickness (CCT) values reported with use of Topcon SP-2000 P and SP-3000 P non-contact specular microscopes since their introduction in 1999 with the two microscopes having been commonly used in a wide range of studies.

METHODS

As a primary resource, PubMed was used to search for peer-reviewed articles in any language that included CCT values obtained with non-contact specular microscopy reported for humans with nominally healthy corneas. Relevant articles were obtained and any cited publications also checked.

RESULTS

A total of 76 articles were identified which reported CCT on different small-to-moderate sized groups of individuals, published between 1999 and 2019. From these, an overall group mean CCT value of 0.525 ± 0.013 mm (median 0.525 mm) can be calculated. An estimated 95 % confidence interval (CI, based on 1.96 SD) would be between 0.500 and 0.550 mm. For the two Topcon models, the group mean ± SD values were 0.529 ± 0.013 mm and 0.517 ± 010 mm respectively. An assessment of the CCT data sets in relation to the reported average age indicated no statistically significant effect (p = 0.289, r = -0.129). Very similar average CCT values were also encountered in 4 other reports where these microscopes were used in large-scale population studies as well as in 2 other reports using the newer Topcon SP-1 P model.

CONCLUSIONS

The Topcon stand-alone non-contact specular microscopes have yielded consistent and predictable corneal thickness measures over many years.

摘要

背景

本研究旨在评估自 1999 年 Topcon SP-2000P 和 SP-3000P 非接触式共焦显微镜推出以来,这两种显微镜在广泛的研究中被普遍使用,报告的中央角膜厚度(CCT)值的一致性。

方法

作为主要资源,我们使用 PubMed 检索了以任何语言发表的包含健康角膜的人类非接触共焦显微镜获得的 CCT 值的同行评议文章。获得了相关文章,并检查了引用的出版物。

结果

共确定了 76 篇文章,这些文章报告了不同的小规模至中等规模的个体 CCT 值,发表时间在 1999 年至 2019 年之间。从这些文章中,可以计算出总体组平均 CCT 值为 0.525±0.013mm(中位数为 0.525mm)。估计 95%置信区间(基于 1.96 SD)为 0.500 至 0.550mm。对于这两种 Topcon 型号,组平均±SD 值分别为 0.529±0.013mm 和 0.517±010mm。对 CCT 数据集与报告的平均年龄的评估表明,没有统计学上的显著影响(p=0.289,r=-0.129)。在其他 4 份报告中也遇到了非常相似的平均 CCT 值,这些报告中使用了这些显微镜进行了大规模的人群研究,以及在另外 2 份使用更新的 Topcon SP-1P 模型的报告中也遇到了非常相似的平均 CCT 值。

结论

多年来,Topcon 独立的非接触式共焦显微镜提供了一致和可预测的角膜厚度测量值。