Karadeniz Technical University Faculty of Medicine, Department of Ophthalmology, Trabzon, Turkey.
University of Health Sciences Turkey, Fethi Sekin City Hospital, Clinic of Ophthalmology, Elazığ, Turkey.
Turk J Ophthalmol. 2020 Oct 30;50(5):271-274. doi: 10.4274/tjo.galenos.2020.57702.
To evaluate the effect of body position on intraocular pressure (IOP) measurement in the pediatric age group.
Children whose general condition was healthy and ophthalmic examination was within normal limits were included. Forty-nine eyes of 49 pediatric patients were included in the study. IOP was measured with an ICARE rebound tonometer (ICARE PRO; ICARE, Helsinki, Finland) while patients were in standing, sitting, and supine positions. Differences between the consecutive measurements were compared statistically.
Twenty-two of the 49 patients were female, 27 were male. The mean age was 9.61±2.66 (5-15) years. Mean IOP values in the standing, sitting, and supine positions were 18.81±2.97 (11.6-26.2) mmHg, 18.88±3.44, (12-28.2) mmHg, and 19.01±2.8 (13.5-25.9) mmHg, respectively. There were no statistically significant differences in pairwise comparisons of the measurements taken in the different positions (p=0.846, p=0.751, p=0.606). There was a statistically significant correlation between corneal thickness and intraocular pressure values in all measurements (p=0.001, r=0.516).
IOP values measured with the ICARE rebound tonometer in healthy children are not affected by body position.
评估体位对儿童眼内压(IOP)测量的影响。
纳入一般情况良好且眼科检查正常的儿童。本研究纳入了 49 例儿童的 49 只眼。使用 ICARE 回弹眼压计(ICARE PRO;ICARE,芬兰赫尔辛基)在患儿站立、坐立和仰卧位时测量 IOP。对连续测量值之间的差异进行统计学比较。
49 例患儿中 22 例为女性,27 例为男性。平均年龄为 9.61±2.66(5-15)岁。站立位、坐立位和仰卧位的平均 IOP 值分别为 18.81±2.97(11.6-26.2)mmHg、18.88±3.44(12-28.2)mmHg 和 19.01±2.8(13.5-25.9)mmHg。不同体位测量值之间的两两比较无统计学差异(p=0.846、p=0.751、p=0.606)。所有测量值中角膜厚度与眼内压值之间均存在统计学显著相关性(p=0.001,r=0.516)。
使用 ICARE 回弹眼压计在健康儿童中测量的 IOP 值不受体位影响。