Cummings School of Veterinary Medicine at Tufts University, North Grafton, MA, USA.
Vet Clin Pathol. 2020 Dec;49(4):614-617. doi: 10.1111/vcp.12915. Epub 2020 Dec 22.
Lactate concentrations can increase with hypoperfusion in dogs and could be used as a prognostic indicator in sick dogs. In a busy emergency service, sample evaluation could be delayed. However, sample evaluation delays have been shown to cause lactate concentration increases in healthy dogs. In sick dogs, the magnitude of increased lactate is unknown. The goal of this study was to prospectively evaluate the effect of room temperature storage times on lactate measurements in dogs presenting to an emergency service.
We evaluated the precision and accuracy of the NOVA Lactate Plus, using standard procedures. To assess the impact of time on lactate concentrations in sick dogs, we prospectively enrolled dogs presenting to an emergency service. Lactate concentrations were measured at six time points using samples stored at room temperature. A Friedman test, followed by a Wilcoxon rank test with a Bonferroni correction was used to evaluate time points.
Forty-five dogs were enrolled in this prospective observational study. The Lactate Plus and table-top analyzer compared favorably, with an R of .98, and a mean bias of 0.26 in 50 canine samples. Precision was acceptable, with a percent coefficient of variation of 5.39. Statistically significant increases in lactate concentrations were found at all time points over baseline (P = .008).
In as little as 7.5 minutes, lactate concentrations increased significantly in samples stored at room temperature. Dogs with lower initial lactate concentrations had had higher increases in lactate concentration percentages over 90 minutes.
在犬中,乳酸浓度会随着低灌注而增加,并且可以作为患病犬的预后指标。在繁忙的急诊服务中,样本评估可能会延迟。然而,已有研究表明,健康犬的乳酸浓度会因样本评估延迟而增加。在患病犬中,乳酸浓度增加的幅度尚不清楚。本研究的目的是前瞻性评估在急诊就诊犬中,室温储存时间对乳酸测量的影响。
我们使用标准程序评估了 NOVA Lactate Plus 的精密度和准确度。为了评估时间对患病犬乳酸浓度的影响,我们前瞻性地招募了急诊就诊的犬。使用室温储存的样本,在六个时间点测量乳酸浓度。使用 Friedman 检验,随后使用带有 Bonferroni 校正的 Wilcoxon 秩检验来评估时间点。
本前瞻性观察研究纳入了 45 只犬。Lactate Plus 和台式分析仪比较结果良好,在 50 个犬样本中 R 为.98,平均偏差为 0.26。精密度可接受,变异系数为 5.39%。与基线相比,所有时间点的乳酸浓度均有统计学显著增加(P =.008)。
在室温下储存的样本中,乳酸浓度在短短 7.5 分钟内就显著增加。初始乳酸浓度较低的犬,其乳酸浓度百分比在 90 分钟内的增加幅度更高。