Clinic of Conservative and Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Plattenstrasse 11, 8032, Zurich, Switzerland.
BMC Oral Health. 2021 Jan 7;21(1):25. doi: 10.1186/s12903-020-01384-0.
To assess the changes of implant surfaces of different roughness after instrumentation with ultrasonic-driven scaler tips of different materials.
Experiments were performed on two moderately rough surfaces (I-Inicell® and II-SLA®), one surface without pre-treatment (III) and one smooth machined surface (IV). Scaler tips made of steel (A), PEEK (B), titanium (C), carbon (D) and resin (E) were used for instrumentation with a standardized pressure of 100 g for ten seconds and under continuous automatic motion. Each combination of scaler tip and implant surface was performed three times on 8 titanium discs. After instrumentation roughness was assessed by profilometry, morphological changes were assessed by scanning electron microscopy, and element distribution on the utmost surface by energy dispersive X-ray spectroscopy.
The surface roughness of discs I and II were significantly reduced by instrumentation with all tips except E. For disc III and IV roughness was enhanced by tip A and C and, only for IV, by tip D. Instrumentation with tips B, D and E left extensive residuals on surface I, II and III. The element analysis of these deposits proved consistent with the elemental composition of the respective tip materials.
All ultrasonic instruments led to microscopic alterations of all types of implants surfaces assessed in the present study. The least change of implant surfaces might result from resin or carbon tips on machined surfaces.
评估不同材料的超声驱动洁牙器头在器械处理后对不同粗糙度种植体表面的影响。
在两个中度粗糙表面(I-Inicell®和 II-SLA®)、一个未经预处理的表面(III)和一个光滑的机械加工表面(IV)上进行实验。使用钢(A)、PEEK(B)、钛(C)、碳(D)和树脂(E)制成的洁牙器头,在 100 克的标准压力下,以连续自动运动的方式处理 10 秒。每种洁牙器头和种植体表面的组合在 8 个钛盘中各进行三次。器械处理后,通过轮廓仪评估粗糙度,通过扫描电子显微镜评估形貌变化,通过能谱仪评估最表面的元素分布。
除 E 型洁牙器头外,所有洁牙器头处理后,I 型和 II 型盘的表面粗糙度均显著降低。A 型和 C 型洁牙器头处理后,III 型和 IV 型盘的粗糙度增加,而仅在 IV 型盘上,D 型洁牙器头也会增加粗糙度。B、D 和 E 型洁牙器头在 I、II 和 III 型盘上留下了广泛的残留物。对这些沉积物的元素分析证明与各自洁牙器头材料的元素组成一致。
本研究评估的所有类型种植体表面,所有超声器械均导致微观改变。在机械加工表面上使用树脂或碳洁牙器头可能对种植体表面的改变最小。