Suppr超能文献

植入Ti-6Al-4V ELI对斯普拉格-道利大鼠股骨骨缺损再生的影响。

Effect of Implantation Ti-6Al-4V ELI in femoral bone defect regeneration of Sprague Dawley rat.

作者信息

Jujur I Nyoman, Devy Kartika, Suha Shovy, Bachtiar Boy Muchlis, Bachtiar Endang Winiati

机构信息

Center for Materials Technology, Agency for the Assessment and Application of Technology (BPPT), Tangerang Selatan, Indonesia.

Departement of Oral Biology, Faculty of Dentistry, Universitas Indonesia, Jakarta, Indonesia.

出版信息

J Adv Pharm Technol Res. 2020 Oct-Dec;11(4):202-206. doi: 10.4103/japtr.JAPTR_74_20. Epub 2020 Oct 10.

Abstract

Ti-6Al-4V ELI is one of the most commonly used dental implant restore function. The solution treatment temperature variation can significantly increase the strength, but it is not yet known the effect of these temperature variations on the alloy's biocompatibility properties. Twelve female Sprague Dawley rats were divided into six groups as follows: the treated group, the control group, and the defect group without implant material. In the treated group, the femur bone defect was implanted with as-cast Ti-6Al-4V ELI, 850°C, 950°C, and 1050°C heat-treated Ti-6Al-4V ELI implant material. The rats were euthanized after 30 days postimplantation and evaluated histologically. The results show that the histological scoring of the specimen for femur defect without implant material is 2 (fibrous union and fibrocartilaginous), score with implant as-cast is 2.5, the sample with 850°C heat treatment material is 2.5, 950°C is 2.5, and the temperature at 1050°C is 2.5. The score of 2.5 is between score 2 and score 3: hemorrhage, fibrous union, fibrocartilaginous microhemorrhage, and mineralized cartilage union. In conclusion, there is no effect of different heat treatment temperatures for Ti-6Al-4V ELI implant material in rat bone regeneration's maturation level.

摘要

Ti-6Al-4V ELI是最常用于牙科植入物恢复功能的材料之一。固溶处理温度变化可显著提高强度,但这些温度变化对合金生物相容性特性的影响尚不清楚。将12只雌性Sprague Dawley大鼠分为以下六组:治疗组、对照组和无植入材料的缺损组。在治疗组中,股骨骨缺损植入铸态Ti-6Al-4V ELI、850°C、950°C和1050°C热处理的Ti-6Al-4V ELI植入材料。植入后30天对大鼠实施安乐死并进行组织学评估。结果显示,无植入材料的股骨缺损标本组织学评分为2(纤维性愈合和纤维软骨),铸态植入物评分为2.5,850°C热处理材料样本评分为2.5,950°C为2.5,1050°C时评分为2.5。2.5分介于2分和3分之间:出血、纤维性愈合、纤维软骨微出血和矿化软骨愈合。总之,不同热处理温度对Ti-6Al-4V ELI植入材料在大鼠骨再生成熟水平上没有影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/62ab/7784942/6e0a79814c91/JAPTR-11-202-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验