2011 - 2018年上海市公共场所人工水环境军团菌污染状况调查及其致病型别鉴定

[Investigation of Legionella contamination in artificial water environment of public places and identification of its pathogenic types in Shanghai from 2011 to 2018].

作者信息

Kong D C, Xiao W J, Chen M L, Wang G Y, Chen Y X, Zhang X, Chen J, Wu H Y, Chen M, Pan H

机构信息

Institute of Infectious Diseases, Shanghai Municipal Center for Disease Control and Prevention, Shanghai 200336, China.

Shanghai Institutes of Preventive Medicine, Shanghai 200336, China.

出版信息

Zhonghua Yu Fang Yi Xue Za Zhi. 2021 Jan 6;55(1):72-77. doi: 10.3760/cma.j.cn112150-20201122-01391.

Abstract

To understand the epidemiological and pathogenic characteristics of Legionella in artificial water environment of public places in Shanghai from 2011 to 2018, and to provide scientific basis for the prevention and control of Legionellosis. A total of 4 817 samples of artificial water environment were collected from 31 public places in Huangpu, Jing'an, Xuhui and Songjiang districts of Shanghai from 2011 to 2108. Epidemiological characteristics of the collected years and months, regional and site types, and sample types were analyzed. After treatment, culture and isolation of the collected water samples, the positive samples were analyzed for Legionella typing characteristics. The positive rate of Legionella pneumophila was 21.57% (1 039/4 817), of which 96.25% (1 000/1 039) was single type, 84.31% (876/1 039) was Legionella pneumophila type 1, followed by Legionella pneumophila type 7 and 6, which accounted for 4.72% (49/1 039) and 3.75% (39/1 039), respectively, and 29 (29/1 039) were multi-type positive. Further typing. From May to October, the highest positive rates were found in July and August, 27.61%(222/804)and 28.61% (230/804)respectively. There were significant differences between different months (<0.001); the highest positive rates were found in central air-conditioning cooling water and chilled water (32.40%) and there were significant differences among different water samples (<0.001). Legionella pneumophila type 1, type 7 and type 6 were the main diversity distribution characteristics in artificial water environment of different regions, different time, different places and different types of public places. Legionella pneumophila type 1 accounted for the highest proportion, and the proportion of positive samples under different epidemiological characteristics was more than 71.64%. There is relatively serious pollution of Legionella pneumophila type 1 in the artificial water environment of public places in Shanghai. It is necessary to strengthen the disinfection of cooling water/freezing water of central air conditioning in public places in July and August every year.

摘要

了解2011年至2018年上海市公共场所人工水环境中嗜肺军团菌的流行病学及致病特征,为军团病的防控提供科学依据。2011年至2018年,从上海市黄浦区、静安区、徐汇区和松江区的31个公共场所共采集4817份人工水环境样本。分析所采集样本的年份、月份、区域、场所类型及样本类型的流行病学特征。对采集的水样进行处理、培养和分离后,对阳性样本进行嗜肺军团菌分型特征分析。嗜肺军团菌阳性率为21.57%(1039/4817),其中96.25%(1000/1039)为单一型,84.31%(876/1039)为嗜肺军团菌1型,其次是嗜肺军团菌7型和6型,分别占4.72%(49/1039)和3.75%(39/1039),29份(29/1039)为多型阳性。进一步分型显示,5月至10月阳性率最高,分别在7月和8月,分别为27.61%(222/804)和28.61%(230/804)。不同月份之间差异有统计学意义(<0.001);中央空调冷却水和冷冻水阳性率最高(32.40%),不同水样之间差异有统计学意义(<0.001)。嗜肺军团菌1型、7型和6型是不同区域、不同时间、不同场所及不同类型公共场所人工水环境中的主要多样性分布特征。嗜肺军团菌1型占比最高,不同流行病学特征下阳性样本比例均超过71.64%。上海市公共场所人工水环境中嗜肺军团菌1型污染较为严重。每年7月和8月需加强公共场所中央空调冷却水/冷冻水的消毒。