Suppr超能文献

评估精神应激和双重任务条件下老年人心率变异性的 Polar V800 监测仪的有效性。

Validity of the Polar V800 Monitor for Assessing Heart Rate Variability in Elderly Adults under Mental Stress and Dual Task Conditions.

机构信息

The Master Program of Long-Term Care in Aging, Kaohsiung Medical University, Kaohsiung 807378, Taiwan.

Kaohsiung LOHAS Home Care Institution, Kaohsiung 82061, Taiwan.

出版信息

Int J Environ Res Public Health. 2021 Jan 20;18(3):869. doi: 10.3390/ijerph18030869.

Abstract

: Aging may result in autonomic nervous dysfunction. Heart rate variability (HRV) is a non-invasive method to measure autonomic nervous activities. Many studies have shown that HRV contributes to the risk assessment of diseases. A Polar V800 heart rate monitor is a wearable device that measures R-R intervals, but has only been validated in younger adults under limited testing conditions. There is no validation of the V800 under mental stress or in dual task testing conditions. Therefore, this study investigated the validity of the Polar V800 heart rate monitor for assessing R-R intervals and evaluated if there were differences on HRV parameters under different situations in community-dwelling elderly adults. : Forty community-dwelling elderly adults were recruited. Heart rates were recorded via electrocardiogram (ECG) and the V800 under sitting, during an arithmetic test, during a naming test, a self-selected walking velocity test (SSWV), and dual tasks (SSWV performing mental arithmetic test and SSWV performing naming test). Indices of time and frequency domains of HRV were calculated afterwards. The intra-class correlation coefficient (ICC) analysis and effect size were calculated to examine the concurrent validity between the V800 and the ECG. : All HRV indices from the V800 were highly correlated with the ECG under all tested conditions (ICC = 0.995-1.000, < 0.001) and the effect size of bias was small (<0.1). : Overall, the V800 has good validity on the assessment of HRV in community-dwelling elderly adults during sitting, mental arithmetic test, naming test, SSWV, and dual tasks.

摘要

衰老可能导致自主神经功能障碍。心率变异性(HRV)是一种测量自主神经活动的非侵入性方法。许多研究表明,HRV 有助于疾病风险评估。Polar V800 心率监测器是一种可穿戴设备,可测量 R-R 间隔,但仅在年轻成年人中进行了有限测试条件下进行了验证。在心理压力或双重任务测试条件下,尚未对 V800 进行验证。因此,本研究调查了 Polar V800 心率监测器评估 R-R 间隔的有效性,并评估了在社区居住的老年人不同情况下 HRV 参数是否存在差异。

:本研究共招募了 40 名社区居住的老年人。通过心电图(ECG)和 V800 在坐姿、算术测试期间、命名测试期间、自选步行速度测试(SSWV)和双重任务(SSWV 执行心算测试和 SSWV 执行命名测试)下记录心率。随后计算 HRV 时域和频域指标。通过计算组内相关系数(ICC)分析和效应量来检验 V800 和 ECG 之间的同时效度。

:在所有测试条件下,V800 的所有 HRV 指标与 ECG 高度相关(ICC = 0.995-1.000,<0.001),偏差的效应量较小(<0.1)。

:总体而言,V800 在评估社区居住的老年人坐姿、心算测试、命名测试、SSWV 和双重任务期间的 HRV 方面具有良好的有效性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0199/7908342/d13fca85f5bd/ijerph-18-00869-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验