Suppr超能文献

使用Thoraflex混合人工血管治疗A型主动脉夹层的冷冻象鼻手术后降主动脉容积变化的量化分析

Quantification of volume changes in the descending aorta after frozen elephant trunk procedure using the Thoraflex hybrid prosthesis for type A aortic dissection.

作者信息

Usai Marco Virgilio, Ibrahim Abdulhakim, Oberhuber Alexander, Dell'Aquila Angelo Maria, Martens Sven, Motekallemi Arash, Rukosujew Andreas

机构信息

Department of Vascular and Endovascular Surgery, University Hospital Muenster, Muenster, Germany.

Department of Cardiothoracic Surgery, Division of Cardiac Surgery, University Hospital Muenster, Muenster, Germany.

出版信息

J Thorac Dis. 2021 Jan;13(1):60-66. doi: 10.21037/jtd-20-2356.

Abstract

BACKGROUND

Frozen elephant trunk (FET) is an established approach to reduce late complications of type A aortic dissection (AADA) by diminishing false lumen perfusion. Currently, surface size of aortic lumina are evaluated using Computed tomography (CT). However, this 2D method is prone to error as it evaluates dissection progression slice by slice. Volume measurement on the other hand can overcome this limitation and deliver better insights in aortic remodeling. Therefore, the aim was to quantify volume changes of the descending and abdominal aorta at short- and mid-term follow-up after FET.

METHODS

Between April 2015 and March 2018, 20 patients who underwent surgical repair of AADA using the Thoraflex™ Hybrid Plexus (Vascutek, Terumo Aortic, Scotland) were included in this study. We measured volumetric change before surgical treatment, at discharge, at 12 and at 24 months based on CTAs (Computed tomography angiography). Surfaces and volumes have been analyzed using Aquarius iNtuition (TeraRecon Inc., Foster City, CA, USA).

RESULTS

One hundred fifty-eight volumetric measures were obtained. The findings show a significant increase of volume of the true lumen (TL) while surface measurement of the TL did not show any significant change at other levels besides level C (diaphragm, P=0.00193). Variance analysis showed significant increase of volume, whereas no significant change was seen in false lumen. Post-hoc analysis revealed a significance at 24 months (P=0.047).

CONCLUSIONS

Although previous studies outline the clinical benefit of Thoraflex hybrid prosthesis on short-term follow up, this study provides a more precise understanding of aortic remodeling based on volumetric measurement. Thus, quantification of volume changes should be included for the assessment of optimal follow-up timing and consecutive procedure planning.

摘要

背景

冷冻象鼻支架(FET)是一种通过减少假腔灌注来降低A型主动脉夹层(AADA)晚期并发症的既定方法。目前,使用计算机断层扫描(CT)评估主动脉腔的表面大小。然而,这种二维方法容易出错,因为它是逐层评估夹层进展情况。另一方面,体积测量可以克服这一局限性,并能更好地洞察主动脉重塑情况。因此,本研究的目的是量化FET术后短期和中期随访时降主动脉和腹主动脉的体积变化。

方法

2015年4月至2018年3月期间,本研究纳入了20例使用Thoraflex™ Hybrid Plexus(Vascutek,Terumo Aortic,苏格兰)进行AADA手术修复的患者。我们根据CT血管造影(CTA)测量了手术治疗前、出院时、12个月和24个月时的体积变化。使用Aquarius iNtuition(TeraRecon Inc.,美国加利福尼亚州福斯特城)分析表面和体积。

结果

共获得158次体积测量值。结果显示,真腔(TL)体积显著增加,而除C水平(膈肌,P=0.00193)外,TL的表面测量在其他水平未显示任何显著变化。方差分析显示体积显著增加,而假腔未见显著变化。事后分析显示在24个月时有显著性差异(P=0.047)。

结论

尽管先前的研究概述了Thoraflex混合假体在短期随访中的临床益处,但本研究基于体积测量提供了对主动脉重塑更精确的理解。因此,在评估最佳随访时间和连续手术规划时应包括体积变化的量化。