The L.p.SG1 DETECT Kit is a rapid, quantitative method for the detection and enumeration of Legionella pneumophila serogroup 1 (L.p. SG1) bacteria from different water matrixes. The method is based on a combination of immunomagnetic separation (IMS) and flow cytometric (FCM) quantification. To this end, the method employs magnetic particles conjugated to anti-L.p. SG1 antibodies for the IMS of the target bacteria from environmental matrices and fluorescently labeled anti-L.p. SG1 antibodies for subsequent quantification by FCM. The IMS can be performed either manually with a magnetic rack (rqmicro.MIMS) or automated with the rqmicro.STREAM sample preparation instrument. Compared to the reference method ISO 11731:2017, which is based on culturing and enumeration of colony forming units (CFU) on agar plates, and can take up to 10 days until results are available, analysis with the L.p. SG1 DETECT Kit is culture-independent and delivers results within 2 h. This Performance Tested Method validation study demonstrates a robust method with recoveries exceeding 69%, inclusivity of 100%, exclusivity of 97.2%, and a shelf life of at least 6 months at 4°C or 40 days at 25°C. The Limit of Detection (LOD) was determined at 21 CFU/L and the Limit of Quantification (LOQ) at 80 CFU/L for potable water using the rqmicro.STREAM. The matrix study across three different types of water matrixes (potable, surface, and industrial process water), demonstrates superior repeatability and reproducibility, as well as equivalent or even superior detection of L.p. SG1 bacteria compared to the standard ISO 11731 method.
L.p.SG1 DETECT 试剂盒是一种快速、定量的方法,用于从不同水基质中检测和计数嗜肺军团菌血清群 1(L.p. SG1)细菌。该方法基于免疫磁分离(IMS)和流式细胞术(FCM)定量的组合。为此,该方法采用与抗 L.p. SG1 抗体偶联的磁性颗粒进行 IMS,从环境基质中分离目标细菌,并使用荧光标记的抗 L.p. SG1 抗体进行后续 FCM 定量。IMS 可以手动使用磁性架(rqmicro.MIMS)或使用 rqmicro.STREAM 样品制备仪器进行自动化。与基于培养和在琼脂平板上计数菌落形成单位(CFU)的参考方法 ISO 11731:2017 相比,该方法无需培养,可在 2 小时内得出结果。与 L.p. SG1 DETECT 试剂盒的分析相比,这种经过性能测试的方法验证研究表明,该方法具有回收率超过 69%、包容性为 100%、排他性为 97.2%的稳健方法,在 4°C 下至少有 6 个月的保质期,在 25°C 下至少有 40 天的保质期。使用 rqmicro.STREAM,在饮用水中的检测限(LOD)确定为 21 CFU/L,定量限(LOQ)为 80 CFU/L。通过对三种不同类型的水基质(饮用水、地表水和工业过程水)进行的基质研究,该方法表现出优异的重复性和再现性,以及与标准 ISO 11731 方法相当或甚至更高的 L.p. SG1 细菌检测能力。