Allegra S, Girardot F, Grattard F, Berthelot P, Helbig J H, Pozzetto B, Riffard S
Université de Lyon; 42023 Université de Saint-Etienne; Groupe Immunité des Muqueuses et Agents Pathogènes, EA 3064, Faculté de Médecine,
J Appl Microbiol. 2011 Apr;110(4):952-61. doi: 10.1111/j.1365-2672.2011.04955.x.
Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic-associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90-431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture.
This study was conducted on 51 environmental specimens. The comparison between IMS-culture and standard culture (ISO 11731, 1998; NF T90-431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (XH and XL) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit).
We found that the average performance of IMS culture was higher than the reference method.
由于存在异养相关细菌,使用标准培养方法(ISO 11731, 1998;NF T90 - 431, 2003)时这些细菌常常过度生长,所以从环境样本中分离嗜肺军团菌通常很困难。为了提高从复杂水样(冷却塔水、生物膜)中回收嗜肺军团菌的效率,我们评估了一种免疫磁珠分离(IMS)检测方法,该方法使用针对嗜肺军团菌血清1型脂多糖产生的单克隆抗体并结合培养法。
本研究对51份环境标本进行了检测。依据ISO 17994, 2004标准,基于相对差异(95%置信限)的上限和下限(XH和XL)以及作为最大可接受偏差的D(置信限值)来确定微生物学方法之间的等效性,从而对免疫磁珠分离 - 培养法和标准培养法(ISO 11731, 1998;NF T90 - 431, 2003)进行比较。
我们发现免疫磁珠分离培养法的平均性能高于参考方法。