Abstract

One of the problems concerning the continuous pH-monitoring technique is whether the relationship between pH measured by the electrode and pH in central and/or capillary fetal blood is constant. To test to what extent a fibrin clot deposited on the pH-electrode influenced the recorded value and the sensitivity of the electrode, the following in vitro study was performed. Fibrin was deposited on the pH-electrode by means of thromboplastin and fibrinogen, or by thromboplastin and whole blood. The deposition of a clot was verified by inspection of the electrode in a microscope. The time for stabilization of the recorded pH-value and the recorded pH-value was measured in standard calibration solutions before and after deposition of the fibrin clot and after decomposition of the fibrin clot by plasmin. FDP was measured in the decomposition solution. From the study it was obvious that the stabilization time of the electrode was considerably influenced by deposition of an "unphysiological" fibrin clot, less so if the clot was deposited by means of whole blood. The recorded pH-value was not influenced.

摘要

连续pH监测技术存在的问题之一是,电极测得的pH值与胎儿中心血和/或毛细血管血中的pH值之间的关系是否恒定。为了测试沉积在pH电极上的纤维蛋白凝块在多大程度上影响记录值和电极的灵敏度,进行了以下体外研究。通过凝血活酶和纤维蛋白原,或通过凝血活酶和全血,将纤维蛋白沉积在pH电极上。通过在显微镜下检查电极来验证凝块的沉积。在纤维蛋白凝块沉积之前和之后,以及在纤维蛋白凝块被纤溶酶分解之后,在标准校准溶液中测量记录的pH值的稳定时间和记录的pH值。在分解溶液中测量FDP。从研究中可以明显看出,电极的稳定时间受到“非生理性”纤维蛋白凝块沉积的显著影响,如果凝块是通过全血沉积的,则影响较小。记录的pH值不受影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验