A sensitive method for the simultaneous determination of oxidizable inorganic anions (sulphide, thiocyanate, thiosulphate and nitrite) was developed by use of high-performance liquid chromatography and fluorimetric detection based on the formation of fluorescent cerium(III) by a redox reaction with cerium(IV). The detection limits are 0.1 nmol for both thiocyanate and nitrite, 0.3 nmol for thiosulphate and 0.8 nmol for sulphide per 10-microliters injection volume. This system can be utilized for the determination of salivary thiocyanate and nitrite and serum thiocyanate.

摘要

通过高效液相色谱法和荧光检测法,基于铈(IV)的氧化还原反应形成荧光铈(III),开发了一种同时测定可氧化无机阴离子(硫化物、硫氰酸盐、硫代硫酸盐和亚硝酸盐)的灵敏方法。对于硫氰酸盐和亚硝酸盐,每10微升进样体积的检测限均为0.1纳摩尔;硫代硫酸盐为0.3纳摩尔;硫化物为0.8纳摩尔。该系统可用于测定唾液中的硫氰酸盐和亚硝酸盐以及血清中的硫氰酸盐。