Suppr超能文献

一种利用便携与非便携裂隙灯显微镜对前房深度和房角进行评估的验证研究。

A Study Validating the Estimation of Anterior Chamber Depth and Iridocorneal Angle with Portable and Non-Portable Slit-Lamp Microscopy.

机构信息

Department of Ophthalmology, Keio University School of Medicine, Tokyo 160-8582, Japan.

OUI Inc., Tokyo 160-0022, Japan.

出版信息

Sensors (Basel). 2021 Feb 19;21(4):1436. doi: 10.3390/s21041436.

Abstract

This study assessed the anterior chamber depth (ACD) and iridocorneal angle using a portable smart eye camera (SEC) compared to the conventional slit-lamp microscope and anterior-segment optical coherence tomography (AS-OCT). This retrospective case-control study included 170 eyes from 85 Japanese patients. The correlation between the ACD evaluations conducted with the SEC and conventional slit-lamp was high (r = 0.814). The correlation between the Van-Herick Plus grade obtained using two devices was also high (r = 0.919). A high kappa value was observed for the Van-Herick Plus grading (Kappa = 0.757). A moderate correlation was observed between the ACD measured using AS-OCT and the slit-lamp image acquired with the conventional slit-lamp microscope and SEC (r = 0.609 and 0.641). A strong correlation was observed between the trabecular-iris angle (TIA) measured using AS-OCT and Van-Herick Plus grade obtained with the conventional slit-lamp microscope and SEC (r = 0.702 and 0.764). Strong correlations of ACD evaluation and high kappa value of the Van-Herick Plus grading indicated the adequate subjective assessment function of the SEC. Moderate correlations between the ACD objective measurement and evaluation and strong correlation between the TIA and Van-Herick Plus grade suggested the good objective assessment function of the SEC. The SEC demonstrated adequate performance for ACD evaluation and angle estimation.

摘要

本研究使用便携式智能眼相机 (SEC) 评估前房深度 (ACD) 和房角,与传统的裂隙灯显微镜和眼前段光学相干断层扫描 (AS-OCT) 进行比较。这是一项回顾性病例对照研究,纳入了 85 例日本患者的 170 只眼。SEC 与传统裂隙灯显微镜进行的 ACD 评估之间具有高度相关性 (r = 0.814)。两种设备获得的 Van-Herick Plus 分级之间也具有高度相关性 (r = 0.919)。Van-Herick Plus 分级的kappa 值较高 (Kappa = 0.757)。AS-OCT 测量的 ACD 与传统裂隙灯显微镜和 SEC 采集的裂隙灯图像之间存在中度相关性 (r = 0.609 和 0.641)。AS-OCT 测量的小梁虹膜角 (TIA) 与传统裂隙灯显微镜和 SEC 获得的 Van-Herick Plus 分级之间存在强相关性 (r = 0.702 和 0.764)。ACD 评估的高度相关性和 Van-Herick Plus 分级的高 kappa 值表明 SEC 具有足够的主观评估功能。ACD 客观测量和评估之间的中度相关性以及 TIA 和 Van-Herick Plus 分级之间的强相关性表明 SEC 具有良好的客观评估功能。SEC 在 ACD 评估和角度估计方面表现出足够的性能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4d52/7921911/881f939eed1a/sensors-21-01436-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验