Department of Contact Lens, Sankara Nethralaya, Medical Research Foundation, Chennai, India.
Clin Exp Optom. 2021 Sep;104(7):760-766. doi: 10.1080/08164622.2021.1887703. Epub 2021 Feb 25.
: It is important to investigate the effect of modulus of silicone hydrogel contact lens on meibomian glands. Evaluating meibomian gland health and function in follow-up appointments should be considered, with the option of changing lens modulus.: To evaluate and compare the effect of modulus of elasticity of silicone hydrogel contact lenses on morphological and functional parameters of the meibomian glands.: A prospective study was conducted on soft silicone hydrogel contact lens wearers of different modulus of elasticity and age and gender-matched controls. Morphological and functional parameters were assessed along with standard patient evaluation of the eye dryness questionnaire.: A statistically significant difference was noted in meibomian gland loss in the upper lid (percent) between the low modulus (18.23 ± 6.63) and high modulus group (27.40 ± 10.21) (p < 0.001) and between high modulus (27.40 ± 10.21) and non-contact lens wearers (19.57 ± 7.65) (p = 0.001). The current study reported significantly higher total meiboscore grading in the high modulus group 3 (2-3) compared to the low modulus 2(2-3) (p = 0.007) and non-contact lens wearing groups 2 (2-3) (p = 0.012). Meibum quality was significantly compromised in the high modulus group 1 (0-1) compared to the low modulus 0 (0-0.75) group (p = 0.01). Standard patient evaluation of the eye dryness questionnaire was found to be significantly higher (p = 0.01) in high modulus 4 (2-8) compared to low modulus wearers 2 (2-4). A significant difference was noted (p < 0.001) in corneal staining grading only between high modulus 0 (0-1) and non-contact lens wearers 0 (0-0) group. A positive correlation was noted in the low modulus group between total meiboscore and meibomian gland expressibility (Rs = +0.69, p < 0.001) and also noted between standard patient evaluation of the eye dryness questionnaire scoring and meibomian gland expressibility (Rs = +0.45, p = 0.012) in the high modulus group.: Higher modulus of elasticity of silicone hydrogel contact lens may influence meibomian gland morphology and function over a period of contact lens wear.
:研究硅水凝胶接触镜的模量对睑板腺的影响很重要。在随访中应考虑评估睑板腺的健康和功能,并考虑改变镜片模量。
:评估和比较不同弹性模量的硅水凝胶接触镜对睑板腺形态和功能参数的影响。
:对不同模量弹性的软性硅水凝胶接触镜佩戴者以及年龄和性别匹配的对照组进行前瞻性研究。评估形态和功能参数,并结合干眼问卷对患者进行标准评估。
:上睑睑板腺缺失百分比在低模量组(18.23±6.63)和高模量组(27.40±10.21)之间(p<0.001)以及高模量组(27.40±10.21)和非接触镜佩戴者之间(19.57±7.65)(p=0.001)存在统计学差异。本研究报告称,高模量组 3(2-3)的总睑板腺评分明显高于低模量组 2(2-3)(p=0.007)和非接触镜佩戴组 2(2-3)(p=0.012)。与低模量组 0(0-0.75)组相比,高模量组 1(0-1)的睑脂质量明显受损(p=0.01)。高模量组 4(2-8)的标准患者眼干问卷评估明显高于低模量组 2(2-4)(p=0.01)。高模量组 0(0-1)与非接触镜佩戴者 0(0-0)组之间角膜染色分级差异有统计学意义(p<0.001)。低模量组中总睑板腺评分与睑板腺分泌能力呈正相关(Rs=+0.69,p<0.001),高模量组中标准患者眼干问卷评分与睑板腺分泌能力呈正相关(Rs=+0.45,p=0.012)。
:硅水凝胶接触镜较高的弹性模量可能会影响佩戴接触镜期间的睑板腺形态和功能。