Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China.
Orthopaedic Department, Peking University Third Hospital, Beijing, China.
Orthop Surg. 2021 May;13(3):817-824. doi: 10.1111/os.12846. Epub 2021 Mar 16.
To investigate the cup survivorship, patient satisfaction level, clinical function, and radiographic outcomes of patients who underwent total hip arthroplasty (THA) using electron beam melting (EBM)-produced porous coated titanium cups at mid-term follow up.
A total of 32 patients (32 hips) from five hospitals in China who underwent primary THA using EBM-produced trabecular titanium cups between May and December 2012 were retrospectively reviewed. The inclusion criteria were: (i) patients who underwent THA with the use of EBM-produced cups with possible 7-year follow up; and (ii) patients with follow-up information, including the cup survivorship, patient satisfaction level, and clinical outcomes such as Harris hip score. The exclusion criteria were: (i) patients with neuropathic diseases; and (ii) patients who underwent THA due to neoplastic disease. Five (15.6%) patients were lost to follow up before the 7-year follow-up and, thus, were excluded; none of these patients died due to disease associated with the THA or had undergone removal of their cups as of our last evaluation. The mean age and body mass index of the patients were 59.37 (range: 38.00-69.00) years and 24.51 (range: 16.50-34.10) kg/m , respectively. Thirteen (48.1%) of the patients were female.
The average duration of follow-up was 93.48 (range: 89.00-99.00) months. The median Harris hip score improved from 42.00 (interquartile range: 37.00-49.00) to 97.00 (interquartile range: 92.00-97.00) at the latest follow up (P < 0.001). A total of 18 (66.7%) patients rated their satisfaction level as very satisfied, 6 (22.2%) as satisfied, 2 (7.4%) as neutral and 1 (3.7%) as dissatisfied. No intraoperative or postoperative complications were identified. At the latest follow up, all cups were considered to have achieved osteointegration fixation, with three or more of the five signs evident in the most recent X-ray. However, three cups revealed radiolucent lines with a width of less than 1 mm. The median vertical and horizontal distances between the latest postoperative center of rotation relative to the anatomic center of rotation were 2.50 (interquartile range: -3.10, 6.94) mm superiorly and 3.26 (interquartile range: -8.12, 2.38) mm medially, respectively, at the most recent postoperative follow up. Kaplan-Meier survivorship analysis of cups, with the endpoint defined as postoperative radiolucent lines of less than 1 mm in width in at least two zones, reveals that the 8.25-year survival was 96.3% (95% confidence interval: 76.49%-99.47%).
The mid-term follow-up of patients who underwent primary THA using EBM-produced porous coated titanium cups demonstrated favorable patient satisfaction, good clinical function, excellent survivorship, and adequate biological fixation.
探讨采用电子束熔融(EBM)生产的多孔涂层钛杯行初次全髋关节置换术(THA)患者的中期杯体生存率、患者满意度水平、临床功能和影像学结果。
回顾性分析 2012 年 5 月至 12 月在中国 5 家医院接受 EBM 生产的多孔钛杯行初次 THA 的 32 例(32 髋)患者。纳入标准为:(i)使用 EBM 生产的杯行 THA 并可能进行 7 年随访的患者;(ii)具有随访信息,包括杯体生存率、患者满意度水平和临床结果(如 Harris 髋关节评分)。排除标准为:(i)患有神经病的患者;(ii)因肿瘤疾病而行 THA 的患者。5 例(15.6%)患者在 7 年随访前失访,因此被排除;截至我们最后一次评估,这些患者均未因与 THA 相关的疾病而死亡,也未进行杯体移除。患者的平均年龄和 BMI 分别为 59.37 岁(范围:38.00-69.00)和 24.51 kg/m²(范围:16.50-34.10)。13 例(48.1%)患者为女性。
平均随访时间为 93.48 个月(范围:89.00-99.00)。末次随访时,Harris 髋关节评分中位数从 42.00 分(四分位距:37.00-49.00)改善至 97.00 分(四分位距:92.00-97.00)(P<0.001)。18 例(66.7%)患者对其满意度评分非常满意,6 例(22.2%)满意,2 例(7.4%)中立,1 例(3.7%)不满意。术中或术后均未发生并发症。末次随访时,所有杯体均被认为已实现骨整合固定,最近的 X 射线检查中有五个迹象中的三个或更多个可见。然而,有三个杯体显示宽度小于 1mm 的透亮线。末次术后旋转中心相对于解剖旋转中心的垂直和水平距离中位数分别为 2.50mm(四分位距:-3.10,6.94)上方和 3.26mm(四分位距:-8.12,2.38)内侧,分别在最近的术后随访时。以术后至少两个区域的宽度小于 1mm 的透亮线为术后终点的杯体 Kaplan-Meier 生存率分析显示,8.25 年生存率为 96.3%(95%置信区间:76.49%-99.47%)。
采用 EBM 生产的多孔涂层钛杯行初次 THA 的中期随访结果显示患者满意度高、临床功能良好、生存率高、生物学固定效果满意。