Suppr超能文献

与 4D 血流 MRI 相比,3D 血流 MRI 可减少扫描时间并提高图像质量,用于法洛四联症根治术后患者Fontan 循环的血流动力学评估。

Reduced scan time and superior image quality with 3D flow MRI compared to 4D flow MRI for hemodynamic evaluation of the Fontan pathway.

机构信息

Department of Cardiothoracic Surgery, Leiden University Medical Center, Albinusdreef 2, 2333ZA, Leiden, The Netherlands.

Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.

出版信息

Sci Rep. 2021 Mar 22;11(1):6507. doi: 10.1038/s41598-021-85936-6.

Abstract

Long scan times prohibit a widespread clinical applicability of 4D flow MRI in Fontan patients. As pulsatility in the Fontan pathway is minimal during the cardiac cycle, acquiring non-ECG gated 3D flow MRI may result in a reduction of scan time while accurately obtaining time-averaged clinical parameters in comparison with 2D and 4D flow MRI. Thirty-two Fontan patients prospectively underwent 2D (reference), 3D and 4D flow MRI of the Fontan pathway. Multiple clinical parameters were assessed from time-averaged flow rates, including the right-to-left pulmonary flow distribution (main endpoint) and systemic-to-pulmonary collateral flow (SPCF). A ten-fold reduction in scan time was achieved [4D flow 15.9 min (SD 2.7 min) and 3D flow 1.6 min (SD 7.8 s), p < 0.001] with a superior signal-to-noise ratio [mean ratio of SNRs 1.7 (0.8), p < 0.001] and vessel sharpness [mean ratio 1.2 (0.4), p = 0.01] with 3D flow. Compared to 2D flow, good-excellent agreement was shown for mean flow rates (ICC 0.82-0.96) and right-to-left pulmonary flow distribution (ICC 0.97). SPCF derived from 3D flow showed good agreement with that from 4D flow (ICC 0.86). 3D flow MRI allows for obtaining time-averaged flow rates and derived clinical parameters in the Fontan pathway with good-excellent agreement with 2D and 4D flow, but with a tenfold reduction in scan time and significantly improved image quality compared to 4D flow.

摘要

长扫描时间限制了 4D 流 MRI 在 Fontan 患者中的广泛临床应用。由于心脏周期中 Fontan 通路的脉动性极小,与 2D 和 4D 流 MRI 相比,采集非心电图门控 3D 流 MRI 可减少扫描时间,同时准确获得时间平均临床参数。32 例 Fontan 患者前瞻性地接受了 2D(参考)、3D 和 4D Fontan 通路的 MRI。从时间平均流速评估了多个临床参数,包括右向左肺血流分布(主要终点)和体肺侧支血流(SPCF)。扫描时间减少了十倍[4D 流 15.9 分钟(SD 2.7 分钟)和 3D 流 1.6 分钟(SD 7.8 秒),p<0.001],同时具有更高的信噪比[平均 SNR 比 1.7(0.8),p<0.001]和血管锐利度[平均 SNR 比 1.2(0.4),p=0.01]与 3D 流相比。与 2D 流相比,平均流速(ICC 0.82-0.96)和右向左肺血流分布(ICC 0.97)显示出良好-优秀的一致性。3D 流衍生的 SPCF 与 4D 流显示出良好的一致性(ICC 0.86)。3D 流 MRI 可在 Fontan 通路中获得时间平均流速和衍生的临床参数,与 2D 和 4D 流具有良好至优秀的一致性,但扫描时间减少了十倍,图像质量显著提高,与 4D 流相比。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3640/7985309/b24013dc2b38/41598_2021_85936_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验