Division of Neonatology, MedStar Georgetown University Hospital, Washington, District of Columbia.
Georgetown University School of Medicine, Washington, District of Columbia.
Am J Perinatol. 2022 Dec;39(16):1786-1791. doi: 10.1055/s-0041-1726125. Epub 2021 Mar 23.
Electrolyte, hemoglobin, and bilirubin values are routinely reported with point-of-care (POC) testing for blood gases. Results are rapidly available and require a small blood volume. Yet, these results are underutilized due to noted discrepancies between central laboratory (CL) and POC testing. The study aimed to determine the correlation between POC and CL measurement of electrolytes, hemoglobin, and bilirubin in neonates.
Electrolyte, hemoglobin, and bilirubin results obtained from capillary blood over a 4-month period were analyzed. Each CL value was matched with a POC value from the same sample or another sample less than 1-hour apart. Agreement was determined by measuring the mean difference (MD) between paired samples with 95% limits of agreement (LOA) and Lin's concordance correlation (LCC).
There were 355-paired sodium/potassium, 139 paired hemoglobin, and 197 paired bilirubin values analyzed. POC sodium values were lower (133.5 ± 5.8 mmol/L) than CL (140.2 ± 5.8 mmol/L), <0.00001 with poor agreement (LCC = 0.49; MD = 6.7; 95% LOA: -13.6 to 0.14). POC potassium values were lower (4.6 ± 0.98 mmol/L) than CL (4.98 ± 1.24mEq/L), < 0.0001, but with better concordance and agreement. (LCC = 0.6; MD = 0.4; 95% LOA: -2.3 to 1.4). There were no differences in hemoglobin between POC (14.3 ± 3.2 g/dL) and CL (14.4 ± 3.1 g/dL), = 0.2 with good LCC (0.93) and in bilirubin values between POC (6.0 ± 3.2 mg/dL) and CL (5.8 ± 3.0 mg/dL), MD = 0.18, and = 0.07.
POC Sodium values are lower than CL. POC potassium levels are also lower, but the differences may not be clinically important while hemoglobin and bilirubin levels are similar between POC and CL. As POC potassium, hemoglobin, and bilirubin levels closely reflect CL values, these results can be relied upon to make clinical judgments in neonates.
· Electrolyte, hemoglobin, and bilirubin are available as POC.. · POC sodium and potassium values are lower than CL results.. · Hemoglobin and bilirubin values are similar between POC and CL..
血气即时检验(POC)常报告电解质、血红蛋白和胆红素值,结果可迅速获得,且所需血量少。然而,由于中央检验科(CL)和 POC 检测之间存在明显差异,这些结果的应用并不广泛。本研究旨在确定 POC 和 CL 测量在新生儿中电解质、血红蛋白和胆红素的相关性。
分析了在 4 个月期间从毛细血管血获得的电解质、血红蛋白和胆红素结果。每个 CL 值均与同一样本或相差不到 1 小时的另一样本的 POC 值相匹配。通过测量配对样本的均值差(MD)和 95%一致性界限(LOA),以及 Lin 的一致性相关系数(LCC)来确定一致性。
共分析了 355 对钠/钾、139 对血红蛋白和 197 对胆红素值。POC 钠值(133.5±5.8mmol/L)低于 CL(140.2±5.8mmol/L),差异具有统计学意义(<0.00001),一致性差(LCC=0.49;MD=6.7;95% LOA:-13.6 至 0.14)。POC 钾值(4.6±0.98mmol/L)低于 CL(4.98±1.24mEq/L),差异具有统计学意义(<0.0001),但一致性和一致性更好(LCC=0.6;MD=0.4;95% LOA:-2.3 至 1.4)。POC 血红蛋白值(14.3±3.2g/dL)与 CL(14.4±3.1g/dL)值无差异(=0.2),LCC 良好(0.93),POC 胆红素值(6.0±3.2mg/dL)与 CL(5.8±3.0mg/dL)值无差异(MD=0.18,=0.07)。
POC 钠值低于 CL。POC 钾值也较低,但差异可能无临床意义,而血红蛋白和胆红素值在 POC 和 CL 之间相似。由于 POC 钾、血红蛋白和胆红素值与 CL 值密切相关,因此这些结果可用于临床判断。
·电解质、血红蛋白和胆红素可作为 POC 获得。
·POC 钠和钾值低于 CL 结果。
·POC 和 CL 之间的血红蛋白和胆红素值相似。