Suppr超能文献

成年人调节过程中晶状体内部成分的定量分析。

Quantitative analysis of internal components of the human crystalline lens during accommodation in adults.

机构信息

Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefangroad1095#, Wuhan, 430030, Hubei, China.

School of Human and Social Sciences, University of West London, London, UK.

出版信息

Sci Rep. 2021 Mar 23;11(1):6688. doi: 10.1038/s41598-021-86007-6.

Abstract

To quantitatively analyze changes in the inner components of the human crystalline lens during accommodation in adults. Eyes of 23 subjects were sequentially examined using CASIA2 Optical Coherence Tomography under 0D, - 3D and - 6D accommodation states. The anterior chamber depth (ACD), anterior and posterior crystalline lens radius of the curvature (ALRC and PLRC) were obtained using built-in software. The lens thickness (LT), lenticular nucleus thickness (NT), anterior cortex thickness (ACT), posterior cortex thickness (PCT), anterior and posterior lenticular nucleus radius of the curvature (ANRC and PNRC), anterior and posterior lenticular nucleus vertex (ANV and PNV) were quantified manually with the Image-pro plus software. During accommodation, the ACD became significantly shallower and LT significantly increased. For changes in the lens, the ALRC decreased by an average magnitude (related to accommodative stimuli) 0.44 mm/D, and PLRC decreased 0.09 mm/D. There was no difference for the ACT and PCT in different accommodation states. For lenticular nucleus response, NT increased on average by 30 μm/D. Both the ANRC and PNRC decreased on average by 212 μm/D and 115 μm/D respectively. The ANV moved forward on average by 0.07 mm under - 3D accommodative stimuli and 0.16 mm for - 6D. However, there was no statistically significant difference between different accommodation states in the PNV movement. Under accommodation stimulation, lens thickness changed mainly due to the lenticular nucleus, but not the cortex. For the lenticular nucleus, both the ANRC and PNRC decreased and ANRC changed the most. The anterior surface of the nucleus moved forward while the posterior surface of the nucleus moved backward but only slightly.

摘要

定量分析成年人调节时人眼晶状体内部成分的变化。使用 CASIA2 光学相干断层扫描仪在 0D、-3D 和-6D 调节状态下对 23 名受试者的眼睛进行连续检查。使用内置软件获得前房深度(ACD)、前晶状体曲率半径(ALRC)和后晶状体曲率半径(PLRC)。使用 Image-pro plus 软件手动测量晶状体厚度(LT)、晶状体核厚度(NT)、前皮质厚度(ACT)、后皮质厚度(PCT)、前晶状体核曲率半径(ANRC)和后晶状体核曲率半径(PNRC)、前晶状体核顶点(ANV)和后晶状体核顶点(PNV)。调节时,ACD 明显变浅,LT 明显增加。对于晶状体的变化,ALRC 平均减少(与调节刺激有关)0.44mm/D,PLRC 减少 0.09mm/D。在不同的调节状态下,ACT 和 PCT 没有差异。对于晶状体核的反应,NT 平均增加 30μm/D。ANRC 和 PNRC 平均分别减少 212μm/D 和 115μm/D。在-3D 调节刺激下,ANV 平均向前移动 0.07mm,在-6D 下移动 0.16mm。然而,在不同的调节状态下,PNV 的运动没有统计学上的显著差异。在调节刺激下,晶状体厚度的变化主要是由于晶状体核,而不是皮质。对于晶状体核,ANRC 和 PNRC 均减小,且 ANRC 变化最大。核的前表面向前移动,而后表面向后移动,但仅稍有移动。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f142/7987977/1bfac828eb1b/41598_2021_86007_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验