Zinc determination in serum microsamples can be treated by graphite furnace atomic absorption spectrometry. To reduce the contamination risks and to obtain results as right as possible, the serum has been twenty fold diluted instead of 100-fold diluted (rate frequently obtained). In these conditions, the use as diluent of a 1% Triton X 100 solution or of a 33.7 mmol/l magnesium nitrate did not allow to obtain exact results. Yet, with an 37.8 mmol/l ammonium phosphate solution, the results given by the direct calibration on an aqueous calibration curve were in good accordance with those found with a recommended flame atomic absorption spectrometry method. The within-run RSD of our method was 2.6%.
血清微量样品中的锌测定可采用石墨炉原子吸收光谱法。为降低污染风险并尽可能获得准确结果,血清采用了20倍稀释而非通常的100倍稀释。在这些条件下,使用1% Triton X 100溶液或33.7 mmol/l硝酸镁作为稀释剂无法获得准确结果。然而,使用37.8 mmol/l磷酸铵溶液时,在水溶液校准曲线上直接校准得到的结果与推荐的火焰原子吸收光谱法得到的结果吻合良好。我们方法的批内相对标准偏差为2.6%。