Mimura Tatsuya, Fujishima Hiroshi, Uchio Eiichi, Fukagawa Kazumi, Kawashima Makoto, Kitsu Kazuma, Horikawa Hiroaki, Mizota Atsushi
Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan.
Department of Ophthalmology, Tsurumi University School of Dental Medicine, Yokohama, Kanagawa, Japan.
Clin Optom (Auckl). 2021 Mar 25;13:93-101. doi: 10.2147/OPTO.S297531. eCollection 2021.
Pollen and proteins attached to soft contact lenses (SCLs) exacerbate allergic conjunctivitis. The material of SCLs may affect the pollen adhesion to the SCLs. The factors associated with the number of pollen particles that are adherent to daily disposable SCL were investigated.
Pollen particles were experimentally exposed to the contact lens surface of 12 types of SCLs for 1 hour, and the SCLs were washed and rinsed with a physiological saline (n=10 for each SCL type). A total of 120 contact lenses were used in this study. The pollen particles attached to the SCL were observed and photographed under a microscope. The influence of the materials of the SCLs on the degree of pollen adhesion were investigated.
The number of residual pollen particles attached to SCLs was in the range from 0-293/area of 200×200 µm. Percentage of pollen adhesion area of the surface of the SCL was in the range from 0.01% to 3.25%. There were significant differences in both the number and adhesion area of pollen particles among the 12 types of SCLs tested (<0.0001 and <0.0001, respectively). The number of pollen particles adhered to SCLs was significantly higher in colored SCLs than clear SCLs (unpaired -test, p<0.001). The portion of pollen adhesion area was the lowest in the silicone hydrogel SCLs made with delefilcon-A (0.01 ± 0.02%).
Pollen adhesion in daily disposable SCLs depends on the characteristics and materials of the SCLs and was high in colored SCLs and lowest in delefilcon-A silicone hydrogel SCL. These results suggest that colored SCLs are not preferred during pollen season.
附着在软性隐形眼镜(SCL)上的花粉和蛋白质会加重过敏性结膜炎。SCL的材料可能会影响花粉在SCL上的附着力。本研究调查了与每日更换型一次性SCL上附着的花粉颗粒数量相关的因素。
将花粉颗粒实验性地暴露于12种SCL的镜片表面1小时,然后用生理盐水冲洗SCL(每种SCL类型n = 10)。本研究共使用了120片隐形眼镜。在显微镜下观察并拍摄附着在SCL上的花粉颗粒。研究了SCL材料对花粉附着程度的影响。
附着在SCL上的残留花粉颗粒数量在0 - 293个/200×200 µm区域范围内。SCL表面花粉附着面积的百分比在0.01%至3.25%之间。在所测试的12种SCL中,花粉颗粒的数量和附着面积均存在显著差异(分别为<0.0001和<0.0001)。彩色SCL上附着的花粉颗粒数量显著高于透明SCL(非配对t检验,p<0.001)。用delefilcon - A制成的硅水凝胶SCL的花粉附着面积比例最低(0.01 ± 0.02%)。
每日更换型一次性SCL上的花粉附着力取决于SCL的特性和材料,在彩色SCL上附着力较高,在delefilcon - A硅水凝胶SCL上附着力最低。这些结果表明,在花粉季节不建议使用彩色SCL。