Karmiris Efthymios, Soulantzou Konstantina, Machairoudia Genovefa, Ntravalias Thomas, Tsiogka Anastasia, Chalkiadaki Evangelia
Ophthalmology Department, Hellenic Air Force General Hospital, Athens, Greece.
Ophthalmology Department, Hellenic Air Force General Hospital and Attikon University Hospital, Athens, Greece ; and.
Cornea. 2022 Jan 1;41(1):60-68. doi: 10.1097/ICO.0000000000002722.
To investigate correlations between specular microscopy endothelial parameters and age with corneal densitometry values, as they are presented from a Scheimpflug device, in different levels of the cornea.
Two hundred eighty-four eyes of 142 healthy subjects were included in this observational, prospective study. Corneal densitometry was evaluated with Scheimpflug imaging system in the central 0- to 2-mm annular zone of the cornea, whereas the endothelial cell properties were assessed with the use of a noncontact specular microscope.
Corneal densitometry values of all corneal layers were statistically significant and positively correlated with age. In univariate linear regression analysis among corneal densitometry values and the endothelial parameters, only endothelial cell density (CD) was statistically significant and inversely correlated with densitometry values in all corneal layers. In stepwise multivariate linear regression analysis, after adjustment for age, hexagonality was statistically significant and inversely correlated with posterior densitometry values, whereas coefficient of variation was positively and significantly correlated with the anterior densitometry values. When repeating stepwise multivariate linear regression analysis without adjusting for age, CD was negatively and significantly correlated with corneal densitometry values of all layers, whereas coefficient of variation was positively and significantly correlated with anterior and total corneal densitometry values.
Corneal densitometry increases with age. It is also inversely correlated with CD, and this might be used as an indirect way to assess the status of the corneal endothelium.
研究角膜内皮参数与年龄之间的相关性,以及它们与通过Scheimpflug设备呈现的不同角膜层面的角膜密度测量值之间的关系。
本观察性前瞻性研究纳入了142名健康受试者的284只眼睛。使用Scheimpflug成像系统评估角膜中央0至2毫米环形区域的角膜密度测量值,而使用非接触式角膜内皮显微镜评估内皮细胞特性。
所有角膜层的角膜密度测量值在统计学上具有显著意义,且与年龄呈正相关。在角膜密度测量值与内皮参数的单变量线性回归分析中,仅内皮细胞密度(CD)在统计学上具有显著意义,且与所有角膜层的密度测量值呈负相关。在逐步多变量线性回归分析中,在对年龄进行调整后,六边形性在统计学上具有显著意义,且与后角膜密度测量值呈负相关,而变异系数与前角膜密度测量值呈正相关且具有显著意义。在不调整年龄的情况下重复逐步多变量线性回归分析时,CD与所有层的角膜密度测量值呈负相关且具有显著意义,而变异系数与前角膜和全角膜密度测量值呈正相关且具有显著意义。
角膜密度测量值随年龄增加而升高。它还与CD呈负相关,这可能被用作评估角膜内皮状态的一种间接方法。