Cadnum Jennifer L, Pearlmutter Basya S, Redmond Sarah N, Jencson Annette L, Benner Kevin J, Donskey Curtis J
Research Service, Louis Stokes Cleveland Veterans' Affairs (VA) Medical Center, Cleveland, Ohio.
Case Western Reserve University School of Medicine, Cleveland, Ohio.
Infect Control Hosp Epidemiol. 2022 Mar;43(3):306-311. doi: 10.1017/ice.2021.113. Epub 2021 Apr 16.
To evaluate the use of colorimetric indicators for monitoring ultraviolet-C (UV-C) light delivery to sites in patient rooms.
In laboratory testing, we examined the correlation between changes in color of 2 commercial colorimetric indicators and log10 reductions in methicillin-resistant Staphylococcus aureus (MRSA) and Clostridioides difficile spores with exposure to increasing doses of UV-C from a low-pressure mercury room decontamination device. In patient rooms, 1 of the colorimetric indicators was used to assess UV-C dose delivery to 27 sites in the room.
In laboratory testing, the manufacturer's reference colors for MRSA and C. difficile reduction corresponded with doses of ∼10,000 and 46,000 µJ/cm2; these doses resulted in >3 log10 reductions in MRSA and C. difficile spores, respectively. In patient rooms, the colorimetric indicators demonstrated suboptimal delivery of UV-C dosing to shadowed areas, which was improved by providing cycles on each side of the patient bed rather than in a single position and altering device placement. Increasing duration of exposure increased the number of sites achieving adequate dosing to kill C. difficile spores.
Commercial colorimetric indicators provide rapid and easy-to-interpret information on the UV-C dose delivered to sites in patient rooms. The indicators may be useful for training environmental services personnel and optimizing the effectiveness of UV-C room decontamination devices.
评估比色指示剂用于监测病房内紫外线C(UV-C)光照射部位的情况。
在实验室测试中,我们研究了2种商用比色指示剂颜色变化与耐甲氧西林金黄色葡萄球菌(MRSA)和艰难梭菌孢子在暴露于来自低压汞房间消毒设备不断增加剂量的UV-C时对数减少量之间的相关性。在病房中,使用其中一种比色指示剂评估UV-C剂量传递至病房内27个部位的情况。
在实验室测试中,针对MRSA和艰难梭菌减少的制造商参考颜色分别对应约10,000和46,000 μJ/cm2的剂量;这些剂量分别导致MRSA和艰难梭菌孢子减少>3个对数。在病房中,比色指示剂显示UV-C剂量传递至阴影区域的情况欠佳,通过在病床两侧而非单一位置进行循环以及改变设备放置得以改善。增加暴露持续时间增加了达到足以杀死艰难梭菌孢子剂量的部位数量。
商用比色指示剂可提供关于传递至病房内各部位的UV-C剂量的快速且易于解读的信息。这些指示剂可能有助于培训环境服务人员并优化UV-C房间消毒设备的效果。