Suppr超能文献

评价果糖胺浓度作为糖尿病犬血糖控制的指标标志物。

Evaluation of fructosamine concentration as an index marker for glycaemic control in diabetic dogs.

机构信息

Clinical Department for Small Animals and Horses, University of Veterinary Medicine Vienna, Vienna, Austria.

Department of Pathobiology, Central Laboratory, University of Veterinary Medicine Vienna, Vienna, Austria.

出版信息

Vet Rec. 2022 Jan;190(2):e244. doi: 10.1002/vetr.244. Epub 2021 Apr 19.

Abstract

BACKGROUND

Although fructosamine is a commonly used surrogate marker to assess glycaemic control in diabetic dogs, its diagnostic accuracy has been questioned. The main objective of this study was to evaluate the reliability of fructosamine measurements to diagnose well and poorly controlled diabetes mellitus (DM), using continuous glucose monitoring as a gold standard.

METHODS

Twenty-four dogs with treated DM and continuous glucose monitoring for mean (±SD) 13.1 (±1.7) days were retrospectively analysed. Two assessment strategies were applied to categorize glycaemic control, and fructosamine concentrations were determined shortly after sensor cessation using a colorimetric assay.

RESULTS

Correlations of individual fructosamine concentrations with mean glucose as well as percentage of measurements > 15 mmol/L were not significant (p = 0.372, p = 0.129). Fructosamine did not differ between dogs with and without hypoglycaemic episodes (p = 0.64). Receiver operating characteristic analysis for fructosamine to diagnose either good or poor glycaemic control revealed AUC values of 0.71 (p = 0.025) indicating moderate accuracy, and 0.7 (p = 0.135) indicating AUC is non-discriminatory, respectively. The respective positive likelihood ratios for the optimal cutoffs to identify good (<396 μmol/L) and poor control (>449 μmol/L) were three.

CONCLUSIONS

Fructosamine measurement is an imperfect surrogate marker for classifying glycaemic control in diabetic dogs and can only complement serial glucose measurements.

摘要

背景

尽管果糖胺常被用作评估糖尿病犬血糖控制的替代标志物,但它的诊断准确性一直受到质疑。本研究的主要目的是使用连续血糖监测作为金标准,评估果糖胺测量值诊断血糖控制良好和较差的糖尿病的可靠性。

方法

回顾性分析了 24 只接受治疗的糖尿病犬,这些犬接受了平均(±SD)13.1(±1.7)天的连续血糖监测。应用了两种评估策略来分类血糖控制,在传感器停止使用后不久,使用比色法测定果糖胺浓度。

结果

个体果糖胺浓度与平均血糖以及>15mmol/L 的测量百分比之间的相关性无统计学意义(p=0.372,p=0.129)。无低血糖发作的犬与有低血糖发作的犬之间的果糖胺浓度无差异(p=0.64)。用于诊断血糖控制良好或不良的果糖胺的受试者工作特征曲线分析显示 AUC 值分别为 0.71(p=0.025)和 0.7(p=0.135),表明中度准确性和 AUC 无鉴别力,分别。最佳截断值识别良好(<396μmol/L)和控制不佳(>449μmol/L)的阳性似然比分别为 3。

结论

果糖胺测量值是一种评估糖尿病犬血糖控制的不完美替代标志物,只能补充连续血糖测量值。