Suppr超能文献

高灵敏可激活 MRI 探针用于检测髓过氧化物酶活性

Highly Efficient Activatable MRI Probe to Sense Myeloperoxidase Activity.

机构信息

Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, Massachusetts 02129, United States.

Center for Systems Biology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, United States.

出版信息

J Med Chem. 2021 May 13;64(9):5874-5885. doi: 10.1021/acs.jmedchem.1c00038. Epub 2021 May 4.

Abstract

Myeloperoxidase (MPO) is a key component of innate immunity but can damage tissues when secreted abnormally. We developed a new generation of a highly efficient MPO-activatable MRI probe (heMAMP) to report MPO activity. heMAMP has improved Gd stability compared to bis-5-HT-Gd-DTPA (MPO-Gd) and demonstrates no significant cytotoxicity. Importantly, heMAMP is more efficiently activated by MPO compared to MPO-Gd, 5HT-DOTA(Gd), and 5HT-DOTAGA-Gd. Molecular docking simulations revealed that heMAMP has increased rigidity via hydrogen bonding intramolecularly and improved binding affinity to the active site of MPO. In animals with subcutaneous inflammation, activated heMAMP showed a 2-3-fold increased contrast-to-noise ratio (CNR) compared to activated MPO-Gd and 4-10 times higher CNR compared to conventional DOTA-Gd. This increased efficacy was further confirmed in a model of unstable atherosclerotic plaque where heMAMP demonstrated a comparable signal increase and responsiveness to MPO inhibition at a 3-fold lower dosage compared to MPO-Gd, further underscoring heMAMP as a potential translational candidate.

摘要

髓过氧化物酶(MPO)是先天免疫的关键组成部分,但当异常分泌时会损伤组织。我们开发了一种新型高效的 MPO 激活型 MRI 探针(heMAMP)来报告 MPO 活性。与双-5-HT-Gd-DTPA(MPO-Gd)相比,heMAMP 具有提高的 Gd 稳定性,并且没有明显的细胞毒性。重要的是,与 MPO-Gd、5HT-DOTA(Gd)和 5HT-DOTAGA-Gd 相比,heMAMP 被 MPO 更有效地激活。分子对接模拟表明,heMAMP 通过分子内氢键增加了刚性,并提高了与 MPO 活性位点的结合亲和力。在皮下炎症的动物中,与激活的 MPO-Gd 相比,激活的 heMAMP 显示出 2-3 倍的对比噪声比(CNR)增加,与常规的 DOTA-Gd 相比,CNR 增加了 4-10 倍。在不稳定的动脉粥样硬化斑块模型中,这种功效的提高得到了进一步证实,与 MPO-Gd 相比,heMAMP 显示出相同的信号增加和对 MPO 抑制的反应性,剂量降低了 3 倍,进一步强调了 heMAMP 作为一种潜在的转化候选物。

相似文献

1
Highly Efficient Activatable MRI Probe to Sense Myeloperoxidase Activity.高灵敏可激活 MRI 探针用于检测髓过氧化物酶活性
J Med Chem. 2021 May 13;64(9):5874-5885. doi: 10.1021/acs.jmedchem.1c00038. Epub 2021 May 4.

引用本文的文献

7
Nanomedicine for Diagnosis and Treatment of Atherosclerosis.纳米医学用于动脉粥样硬化的诊断和治疗。
Adv Sci (Weinh). 2023 Dec;10(36):e2304294. doi: 10.1002/advs.202304294. Epub 2023 Oct 28.

本文引用的文献

8
Deformylation reaction-based probe for imaging of HOCl.用于次氯酸成像的基于脱甲酰基反应的探针。
Chem Sci. 2017 Nov 3;9(2):495-501. doi: 10.1039/c7sc03784h. eCollection 2018 Jan 14.
9
The New Restrictions on the Use of Linear Gadolinium-based Contrast Agents in Japan.日本对线性钆基造影剂使用的新限制
Magn Reson Med Sci. 2019 Jan 10;18(1):1-3. doi: 10.2463/mrms.e.2017-0176. Epub 2018 Mar 16.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验