Suppr超能文献

基于眼动的青光眼和神经眼科视野缺损的知觉后果评估。

Eye-Movement-Based Assessment of the Perceptual Consequences of Glaucomatous and Neuro-Ophthalmological Visual Field Defects.

机构信息

Department of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi, India.

Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, The Netherlands.

出版信息

Transl Vis Sci Technol. 2021 Feb 5;10(2):1. doi: 10.1167/tvst.10.2.1.

Abstract

PURPOSE

Assessing the presence of visual field defects (VFD) through procedures such as perimetry is an essential aspect of the management and diagnosis of ocular disorders. However, even the latest perimetric methods have shortcomings-a high cognitive demand and requiring prolonged stable fixation and feedback through a button response. Consequently, an approach using eye movements (EM)-as a natural response-has been proposed as an alternate way to evaluate the presence of VFD. This approach has given good results for computer-simulated VFD. However, its use in patients is not well documented yet. Here we use this new approach to quantify the spatiotemporal properties (STP) of EM of various patients suffering from glaucoma and neuro-ophthalmological VFD and controls.

METHODS

In total, 15 glaucoma patients, 37 patients with a neuro-ophthalmological disorder, and 21 controls performed a visual tracking task while their EM were being recorded. Subsequently, the STP of EM were quantified using a cross-correlogram analysis. Decision trees were used to identify the relevant STP and classify the populations.

RESULTS

We achieved a classification accuracy of 94.5% (TPR/sensitivity = 96%, TNR/specificity = 90%) between patients and controls. Individually, the algorithm achieved an accuracy of 86.3% (TPR for neuro-ophthalmology [97%], glaucoma [60%], and controls [86%]). The STP of EM were highly similar across two different control cohorts.

CONCLUSIONS

In an ocular tracking task, patients with VFD due to different underlying pathology make EM with distinctive STP. These properties are interpretable based on different clinical characteristics of patients and can be used for patient classification.

TRANSLATIONAL RELEVANCE

Our EM-based screening tool may complement existing perimetric techniques in clinical practice.

摘要

目的

通过视野计等程序评估视野缺损(VFD)的存在是眼部疾病管理和诊断的重要方面。然而,即使是最新的视野计方法也存在缺陷——认知需求高,需要通过按钮反应长时间稳定固定和反馈。因此,已经提出了一种使用眼球运动(EM)作为自然反应的方法来评估 VFD 的存在。这种方法在计算机模拟的 VFD 中取得了很好的结果。然而,其在患者中的应用尚未得到很好的记录。在这里,我们使用这种新方法来量化患有青光眼和神经眼科 VFD 以及对照组的各种患者的 EM 的时空特性(STP)。

方法

总共 15 名青光眼患者、37 名患有神经眼科疾病的患者和 21 名对照者在进行视觉跟踪任务的同时记录他们的 EM。随后,使用互相关图分析来量化 EM 的 STP。决策树用于识别相关的 STP 并对人群进行分类。

结果

我们在患者和对照组之间实现了 94.5%的分类准确性(TPR/敏感性=96%,TNR/特异性=90%)。单独来看,该算法的准确性为 86.3%(神经眼科的 TPR[97%]、青光眼[60%]和对照组[86%])。EM 的 STP 在两个不同的对照组之间非常相似。

结论

在眼部跟踪任务中,由于不同潜在病理原因导致 VFD 的患者会产生具有独特 STP 的 EM。这些特性可以根据患者的不同临床特征进行解释,并可用于患者分类。

翻译

吴萤萤

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6c0a/7873497/e12f2c7636d0/tvst-10-2-1-f001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验