Suppr超能文献

使用集成显微镜的光学相干断层扫描技术对白内障超声乳化术中人工晶状体与后囊膜间隙进行定量分析

Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification.

作者信息

Nagpal Ritu, Shakkarwal Chetan, Agarwal Rinky, Bafna Rahul Kumar, Maharana Prafulla Kumar, Sharma Namrata

机构信息

Cataract, Cornea & Refractive Surgery Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.

出版信息

Clin Ophthalmol. 2021 May 10;15:1965-1970. doi: 10.2147/OPTH.S292799. eCollection 2021.

Abstract

PURPOSE

To quantitatively analyze the dimensions of the gap between the intraocular lens (IOL) and the posterior capsule using microscope-integrated optical coherence tomography (MIOCT).

SETTING

Institutional.

DESIGN

Prospective, interventional.

METHODS

A total of 105 eyes of 105 consecutive patients planned for phacoemulsification with IOL implantation were enrolled. At the end of surgery, the gap between the IOL and the posterior capsule (IOL-PC gap) was measured using MIOCT (RESCAN). The same gap was reassessed at 1 week follow-up visit using the Visante-OCT system. The cases were sub-grouped based on the grade of cataract, IOL material, size and design and were analyzed to look for any difference in the IOL-PC gap both intraoperatively and postoperatively.

RESULTS

The IOL-PC gap could be successfully measured intra-operatively in all cases, using the RESCAN. The mean gap at the end of phacoemulsification was 385.08±264.58 µm, and at one week follow up this was 120.83± 95.13 µm.

CONCLUSION

MIOCT may be successfully used to quantify the dimensions of the gap between the IOL and the posterior capsule. It can be used as a potential tool to further understand the dynamics of the IOL-PC space and to assess the impact of various IOL and non-IOL parameters implicated in the causation of posterior capsule opacification.

摘要

目的

使用显微镜集成光学相干断层扫描(MIOCT)对人工晶状体(IOL)与后囊膜之间的间隙尺寸进行定量分析。

设置

机构性研究。

设计

前瞻性、干预性研究。

方法

纳入105例计划行白内障超声乳化吸除联合IOL植入术的连续患者的105只眼。手术结束时,使用MIOCT(RESCAN)测量IOL与后囊膜之间的间隙(IOL-PC间隙)。在1周随访时使用Visante-OCT系统重新评估相同的间隙。根据白内障分级、IOL材料、尺寸和设计对病例进行亚组划分,并分析术中及术后IOL-PC间隙的差异。

结果

使用RESCAN在所有病例中均能成功术中测量IOL-PC间隙。超声乳化吸除术结束时的平均间隙为385.08±264.58 µm,1周随访时为120.83±95.13 µm。

结论

MIOCT可成功用于量化IOL与后囊膜之间间隙的尺寸。它可作为一种潜在工具,用于进一步了解IOL-PC空间的动态变化,并评估各种IOL和非IOL参数对后囊膜混浊形成的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4c5b/8121680/d946354fdd59/OPTH-15-1965-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验