Suppr超能文献

白内障手术后囊膜封闭的光学相干断层扫描评估

Optical coherence tomography assessment of capsule closure after cataract surgery.

作者信息

Sacu Stefan, Findl Oliver, Linnola Reijo J

机构信息

Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.

出版信息

J Cataract Refract Surg. 2005 Feb;31(2):330-6. doi: 10.1016/j.jcrs.2004.04.057.

Abstract

PURPOSE

To develop a technique for documenting and quantifying capsule bend formation in pseudophakic eyes, evaluate when the anterior and posterior lens capsules become completely apposed to the optic, and determine how soon a capsule bend is created at the optic edge of an intraocular lens (IOL) after cataract surgery.

SETTING

Medical University of Vienna, Department of Ophthalmology, Vienna, Austria.

METHODS

This prospective study comprised 33 eyes of 33 patients with age-related cataract who were scheduled to have cataract surgery. All eyes had phacoemulsification with implantation of 1 of 3 types of open-loop IOLs: 1-piece acrylic (SA60AT, Alcon), 3-piece acrylic (AcrySof MA60BM, Alcon), or 3-piece silicone (911A, AMO). Each group included 11 eyes. One and 3 days and 1, 2, 3, and 4 weeks after surgery, contact between the lens capsule and IOL optic as well as capsule bend formation were evaluated using optical coherence tomography (OCT). The postoperative times at which the capsule came into contact with the IOL optic and when the capsule bend formed were determined.

RESULTS

One day postoperatively, the mean distance between the anterior capsule and the IOL was 197 microm in the 1-piece acrylic IOL group, 161 microm in the 3-piece acrylic IOL group, and 220 microm in the 3-piece silicone IOL group. The posterior capsule was in contact with the IOL on the same day or earlier than the anterior capsule in 28 patients (85%). Postoperatively, the capsule bend formed at a mean of 10 days in the 1-piece acrylic group, 13 days in the 3-piece acrylic group, and 15 days in the 3-piece silicone group. The short-term reproducibility of the OCT technique was excellent (r = 0.99).

CONCLUSIONS

Optical coherence tomography produced cross-sectional tomograms of capsule-IOL contact in the early postoperative period. There was no significant difference in the time to capsule bend formation between the 3 IOLs. However, capsule bend formation at the optic edge occurred earlier with the 1-piece acrylic IOL than with the 3-piece silicone IOL.

摘要

目的

开发一种记录和量化假晶状体眼中囊袋弯曲形成的技术,评估前后晶状体囊袋何时与人工晶状体光学部完全贴合,并确定白内障手术后人工晶状体(IOL)光学边缘处囊袋弯曲形成的时间。

设置

奥地利维也纳医科大学眼科。

方法

这项前瞻性研究纳入了33例计划进行白内障手术的年龄相关性白内障患者的33只眼。所有眼睛均接受了超声乳化手术,并植入了3种类型的开环IOL中的一种:单片丙烯酸酯(SA60AT,爱尔康)、三片丙烯酸酯(AcrySof MA60BM,爱尔康)或三片硅酮(911A,AMO)。每组包括11只眼。在术后1天、3天以及1、2、3和4周,使用光学相干断层扫描(OCT)评估晶状体囊袋与IOL光学部之间的接触以及囊袋弯曲的形成。确定囊袋与IOL光学部接触的术后时间以及囊袋弯曲形成的时间。

结果

术后1天,单片丙烯酸酯IOL组前囊与IOL之间的平均距离为197微米,三片丙烯酸酯IOL组为161微米,三片硅酮IOL组为220微米。28例患者(85%)的后囊在同一天或早于前囊与IOL接触。术后,单片丙烯酸酯组囊袋弯曲形成的平均时间为10天,三片丙烯酸酯组为13天,三片硅酮组为15天。OCT技术的短期再现性极佳(r = 0.99)。

结论

光学相干断层扫描在术后早期生成了囊袋 - IOL接触的横断面断层图像。三种IOL在囊袋弯曲形成时间上无显著差异。然而,单片丙烯酸酯IOL在光学边缘处的囊袋弯曲形成比三片硅酮IOL更早。