The goal of the present study is to investigate changes in supra-aortic vessel perfusion after implantation of the non-covered Ascyrus Medical Dissection Stent (AMDS) for surgical treatment of acute type A aortic dissection.
From 2017 to 2020, 16 consecutive patients treated with AMDS and involvement (dissection to total occlusion) of at least 1 supra-aortic vessel were included in the study. Centre-line based computed tomography measurements of true, false and total lumen area using Terarecon software were performed before and after surgery. Changes in the true lumen area were indexed to the entire vessel area. The paired sample t-test was used to assess the significance of the observed differences.
Analysis of supra-aortic vessels and the descending aorta showed significant improvement in true lumen perfusion after the AMDS was implanted. The indexed true lumen area increased postoperatively by 72%, 112% and 30% in the innominate, right and left common carotid arteries, respectively. Total occlusions of both common carotid arteries recovered completely after surgical treatment. The proximal- and the mid-descending aorta showed a 78% and 48% improvement of the indexed true lumen area, respectively.
Arch repair using AMDS shows promising results in the treatment of acute type A aortic dissection. Quantitative measurements of true and false lumen perfusion demonstrated a significant increase in true lumen area and a 100% regression of totally occluded supra-aortic branches. Further examination in a larger cohort of patients and comparison with isolated hemiarch repair are needed to confirm positive vascular remodelling after an AMDS implant.
本研究旨在探讨非覆膜 Ascyrus 医疗解剖支架(AMDS)植入治疗急性 A 型主动脉夹层后,升主动脉血管的灌注变化。
2017 年至 2020 年,连续纳入 16 例 AMDS 治疗且至少 1 个升主动脉分支受累(夹层至完全闭塞)的患者。采用 Terarecon 软件对中心线为基础的 CT 测量进行真腔、假腔和总管腔面积。使用配对样本 t 检验评估观察到的差异的显著性。
对升主动脉血管和降主动脉进行分析显示,AMDS 植入后真腔灌注明显改善。无名动脉、右颈总动脉和左颈总动脉的真腔面积指数分别增加了 72%、112%和 30%。完全闭塞的双侧颈总动脉在手术后完全恢复。近端和中段降主动脉的真腔面积指数分别改善了 78%和 48%。
使用 AMDS 进行弓部修复在治疗急性 A 型主动脉夹层方面显示出良好的效果。真腔和假腔灌注的定量测量显示,真腔面积明显增加,完全闭塞的升主动脉分支完全恢复。需要进一步在更大的患者队列中进行检查,并与单独的半弓修复进行比较,以确认 AMDS 植入后的血管重塑是积极的。