Raszewski Zbigniew, Nowakowska Danuta, Więckiewicz Włodzimierz, Nowakowska-Toporowska Agnieszka
Research Assistant, SpofaDental Kerr Company, 506-01 Jičin, Czech Republic.
Department of Prosthodontics, Wroclaw Medical University, 50-425 Wroclaw, Poland.
Polymers (Basel). 2021 May 29;13(11):1800. doi: 10.3390/polym13111800.
Chlorhexidine (CHX)-based dental hygiene products are widely used by dental patients. As these products may have long-term contact with denture poly(methyl methacrylate) (PMMA) resin, anti-discoloration systems (ADSs) were included in them to prevent discoloration of the natural teeth and dental materials. The aim of this study was to evaluate the effect of two newly designed CHX-containing gels with ADSs and two commercial products with ADSs (Curasept 0.5% and Curasept 1%) in preventing staining and to analyze the mechanical properties of heat-curing PMMA denture base resin. Twenty-five discs (five for each test group) of PMMA dental resin with a thickness of 1 mm and a diameter of 20 mm were polymerized according to the manufacturer's instructions and stored in distillate water at a temperature of 37 °C. The surface of the specimens was covered with two commercially available gels-Curasept 1% and Curasept 0.5%, or two experimental gel formulations containing 1% CHX. PMMA specimens stored in distilled water were used as control. The initial values of color and Brinell hardness of the specimens were measured immediately after specimen preparation. The changes in color and Brinell hardness, as well as water sorption, and solubility of the specimens were measured after one year of conditioning. Statistical analysis of the obtained data was performed using one-way analysis of variance and Dunn-Bonferroni post hoc tests. : In the group of specimens covered with gel 1 with citric acid or Curasept 0.5%, the color change was clinically acceptable (ΔE* < 2.7). In the specimens stored in contact with gel 2 with polyvinylpyrrolidone (PVP) and Curasept 1%, the ΔE* values were 3.6 and 3.67, respectively. In the control group, the level of hardness decreased significantly from 150 to 140 during the experiment. In addition, a statistically significant decrease in hardness was observed in specimens stored with Curasept 1% and gel 2 with PVP. Specimens stored in contact with Curasept 0.5% and gel 1 with citric acid also showed a lower hardness, but the change was not statistically significant. The sorption of all the groups of PMMA specimens ranged from 22.83 to 24.47 µg/mm, with no significant differences found between them. All the PMMA specimens stored in contact with the tested CHX gels exhibited a significantly higher solubility (6.84 ± 7.91 µg/mm) compared to the control group (6.74 µg/mm), with the highest solubility noted for specimens stored with Curasept 1%. : The results showed that CHX used in the gel form with ADSs at a concentration of 0.5% and the experimental gel containing 1% CHX with citric acid caused limited changes to the color and mechanical properties of the PMMA denture base resin during the study period. These gels may be safely used by dental patients for oral hygiene regimen even for prolonged periods of time. ADSs contained in these gels seem to be effective in preventing CHX discoloration.
含氯己定(CHX)的口腔卫生产品被牙科患者广泛使用。由于这些产品可能会与义齿聚甲基丙烯酸甲酯(PMMA)树脂长期接触,因此其中包含抗变色系统(ADSs)以防止天然牙齿和牙科材料变色。本研究的目的是评估两种新设计的含ADSs的含CHX凝胶以及两种含ADSs的商业产品(0.5%的Curasept和1%的Curasept)在防止染色方面的效果,并分析热固化PMMA义齿基托树脂的机械性能。将25个厚度为1mm、直径为20mm的PMMA牙科树脂圆盘(每个测试组5个)按照制造商的说明进行聚合,并在37℃的蒸馏水中储存。将样品表面覆盖两种市售凝胶——1%的Curasept和0.5%的Curasept,或两种含1%CHX的实验性凝胶配方。储存在蒸馏水中的PMMA样品用作对照。在样品制备后立即测量其颜色和布氏硬度的初始值。在经过一年的处理后,测量样品的颜色和布氏硬度变化以及吸水率和溶解度。使用单因素方差分析和Dunn-Bonferroni事后检验对获得的数据进行统计分析。:在覆盖有含柠檬酸的凝胶1或0.5%的Curasept的样品组中,颜色变化在临床上是可接受的(ΔE*<2.7)。在与含聚乙烯吡咯烷酮(PVP)的凝胶2和1%的Curasept接触储存的样品中,ΔE*值分别为3.6和3.67。在对照组中,实验期间硬度水平从150显著降至140。此外,在与1%的Curasept和含PVP的凝胶2接触储存的样品中观察到硬度有统计学显著下降。与含0.5%的Curasept和含柠檬酸的凝胶1接触储存的样品也显示出较低的硬度,但变化无统计学意义。所有PMMA样品组的吸水率在22.83至24.47μg/mm之间,它们之间未发现显著差异。与测试的含CHX凝胶接触储存的所有PMMA样品的溶解度(6.84±7.91μg/mm)显著高于对照组(6.74μg/mm),与1%的Curasept接触储存的样品溶解度最高。:结果表明,在研究期间,以0.5%浓度与ADSs以凝胶形式使用的CHX以及含1%CHX和柠檬酸的实验性凝胶对PMMA义齿基托树脂的颜色和机械性能造成的变化有限。这些凝胶即使长时间使用,牙科患者也可安全用于口腔卫生护理方案。这些凝胶中含有的ADSs似乎在防止CHX变色方面有效。