Suppr超能文献

健康丹麦成年人 IgG 亚类浓度的时间相关性变化。

Time-related variation in IgG subclass concentrations in a group of healthy Danish adults.

机构信息

Department of Clinical Immunology, University Hospital, Odense, Denmark.

Department of Oncology, University Hospital, Odense, Denmark.

出版信息

Immun Inflamm Dis. 2021 Sep;9(3):1009-1015. doi: 10.1002/iid3.464. Epub 2021 Jun 2.

Abstract

INTRODUCTION

Immunoglobulin G subclass measurements are important for the diagnostic work-up of immunodeficiencies and immunoglobulin G4 (IgG4) related diseases. It is currently unknown whether a single sampling is truly representative for an individual's IgG subclass concentrations. This study aimed to investigate whether IgG and IgG subclass concentrations in healthy individuals are stable over time.

METHOD

With a span of median 42 weeks, four samples from each of 54 (34M, 20F) healthy adult volunteers (24-66 years) were analyzed for IgG and IgG1-4 using turbidimetry. Concentrations were compared within and between individuals.

RESULTS

IgG and IgG subclass concentrations followed either a normal (IgG, IgG1, and IgG3) or log normal (IgG2 and IgG4) distribution. Immunoglobulin 4 demonstrated by far the widest range of concentrations between individuals (670-fold: 0.004-2.68 g/L). Immunoglobulin G subclass variations within individuals were expressed as pooled standard deviations (PSD). These ranged from 0.056 (IgG4) to 0.955 g/L (IgG) and correlated with mean concentration of IgG or the particular IgG subclass. As a consequence, the relative PSDs (i.e., PSD divided by mean IgG or IgG subclass concentration) fell within a narrow range: 5.82%-10.1%. Based on these numbers, the 95%-upper one-sided confidence limits for intraindividual IgG and IgG subclass variation was calculated to range from 9.82% (IgG2) to 16.9% (IgG4).

CONCLUSION

The study documents that IgG or IgG subclass concentrations within healthy individuals are very stable over at least 42 weeks. The expected variation for IgG4 concentrations at a 95% confidence level does not exceed ±16.9%.

摘要

简介

免疫球蛋白 G 亚类的测量对于免疫缺陷和免疫球蛋白 G4(IgG4)相关疾病的诊断很重要。目前尚不清楚单次采样是否能真实代表个体的 IgG 亚类浓度。本研究旨在探究健康个体的 IgG 和 IgG 亚类浓度是否随时间稳定。

方法

在中位数为 42 周的时间跨度内,对 54 名(34 名男性,20 名女性)健康成年志愿者的 4 个样本进行 IgG 和 IgG1-4 的分析,使用比浊法。比较个体内和个体间的浓度。

结果

IgG 和 IgG 亚类浓度呈正态(IgG、IgG1 和 IgG3)或对数正态(IgG2 和 IgG4)分布。IgG4 个体间的浓度差异最大(670 倍:0.004-2.68 g/L)。个体内 IgG 亚类的变异以汇总标准差(PSD)表示。范围从 0.056(IgG4)到 0.955 g/L(IgG),与 IgG 或特定 IgG 亚类的平均浓度相关。因此,相对 PSD(即 PSD 除以 IgG 或 IgG 亚类的平均浓度)在一个狭窄的范围内:5.82%-10.1%。根据这些数据,计算出个体内 IgG 和 IgG 亚类变异的 95%单侧置信限范围为 9.82%(IgG2)至 16.9%(IgG4)。

结论

该研究证明了健康个体的 IgG 或 IgG 亚类浓度至少在 42 周内非常稳定。在 95%置信水平下,IgG4 浓度的预期变化不超过±16.9%。