一种标准化超声检查方案评估股外侧肌的可靠性和有效性。

Reliability and validity of a standardised ultrasound examination protocol to quantify vastus lateralis muscle.

机构信息

Cardiology, Angiology, Pneumonology, Medical Clinic, University Hospital of Heidelberg, Heidelberg, Germany. E-mail:

出版信息

J Rehabil Med. 2021 Jul 6;53(7):jrm00212. doi: 10.2340/16501977-2854.


DOI:10.2340/16501977-2854
PMID:34121129
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC8638746/
Abstract

OBJECTIVE: To evaluate the reliability and validity of a standardized ultrasound examination protocol for measuring vastus lateralis muscle size. DESIGN: Prospective cohort study. SUBJECTS: Sixteen staff members of the university hospital of Heidelberg. METHODS: Muscle thickness, cross-sectional area and subcutaneous adipose tissue thickness were measured at 3 standardized sites on the right and left vastus lateralis muscle. Ultrasound measurements were collected by 2 independent investigators on 2 different days and compared with magnetic resonance imaging measurements. RESULTS: Intraclass correlation coefficients (ICC) for intra- and inter-rater reliability showed very good closeness of agreement for all parameters (ICC = 0.929-0.994, p < 0.001). Muscle thickness and subcutaneous adipose tissue thickness ultrasound and magnetic resonance imaging measurements revealed good to very good closeness of agreement (ICC = 0.835-0.969, p < 0.001), whereas cross-sectional area showed only average closeness of agreement (ICC = 0.727, p < 0.001). A strong predictive positive correlation for ultrasound and magnetic resonance imaging-based measurements of cross-sectional area was found (R² = 0.793, p < 0.001). CONCLUSION: By standardization of an examination protocol, quantitative vastus lateralis muscle ultrasound proved to be a reliable method for assessing vastus lateralis muscle size. Furthermore, this protocol is valid for measuring muscle thickness and subcutaneous adipose tissue thickness, although there seems to be a systematic underestimation of cross-sectional area depending on subcutaneous adipose tissue thickness.

摘要

目的:评估一种标准化超声检查方案测量股外侧肌大小的可靠性和有效性。

设计:前瞻性队列研究。

受试者:海德堡大学医院的 16 名工作人员。

方法:在股外侧肌的 3 个标准化部位测量肌肉厚度、横截面积和皮下脂肪组织厚度。由 2 名独立的调查员在 2 天内收集超声测量值,并与磁共振成像测量值进行比较。

结果:所有参数的组内和组间可靠性的内类相关系数(ICC)均显示出非常好的一致性(ICC=0.929-0.994,p<0.001)。肌肉厚度和皮下脂肪组织厚度的超声和磁共振成像测量值显示出良好到非常好的一致性(ICC=0.835-0.969,p<0.001),而横截面积仅显示出平均一致性(ICC=0.727,p<0.001)。超声和磁共振成像测量的横截面积之间存在很强的正预测相关性(R²=0.793,p<0.001)。

结论:通过检查方案的标准化,定量股外侧肌超声被证明是一种可靠的方法,可用于评估股外侧肌大小。此外,该方案对于测量肌肉厚度和皮下脂肪组织厚度是有效的,尽管根据皮下脂肪组织厚度,横截面积似乎存在系统低估。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/636428e056a3/JRM-53-7-2809-g005.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/8e5c4d838091/JRM-53-7-2809-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/a31a6326066d/JRM-53-7-2809-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/63c60ce7f7ce/JRM-53-7-2809-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/adf2a8728e64/JRM-53-7-2809-g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/636428e056a3/JRM-53-7-2809-g005.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/8e5c4d838091/JRM-53-7-2809-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/a31a6326066d/JRM-53-7-2809-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/63c60ce7f7ce/JRM-53-7-2809-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/adf2a8728e64/JRM-53-7-2809-g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ba3d/8638746/636428e056a3/JRM-53-7-2809-g005.jpg

相似文献

[1]
Reliability and validity of a standardised ultrasound examination protocol to quantify vastus lateralis muscle.

J Rehabil Med. 2021-7-6

[2]
Correcting for subcutaneous fat: Does it improve the correlation between vastus lateralis echo intensity and physical performance in older women?

Clin Physiol Funct Imaging. 2022-9

[3]
Can ultrasound measurements of muscle thickness be used to measure the size of individual quadriceps muscles in people with patellofemoral pain?

Phys Ther Sport. 2015-2

[4]
Variability of regional quadriceps echo intensity in active young men with and without subcutaneous fat correction.

Appl Physiol Nutr Metab. 2020-7

[5]
The primacy of ultrasound in the assessment of muscle architecture: precision, accuracy, reliability of ultrasonography. Physiatrist, radiologist, general internist, and family practitioner's experiences.

Rev Assoc Med Bras (1992). 2019-2

[6]
Influence of subcutaneous adipose thickness and dominance on reliability of quadriceps muscle quality in healthy young individuals.

J Ultrasound. 2022-9

[7]
Intra- and inter-rater reliability of muscle and fat thickness measurements obtained using portable ultrasonography in older adults.

Clin Nutr ESPEN. 2024-4

[8]
Validity and reliability of high-resolution ultrasound imaging for the assessment of regional body composition in stage 5 chronic kidney disease patients undergoing continuous ambulatory peritoneal dialysis.

Perit Dial Int. 2022-1

[9]
Validity of measuring distal vastus medialis muscle using rehabilitative ultrasound imaging versus magnetic resonance imaging.

Man Ther. 2014-6

[10]
Reliability of point-of-care ultrasound for measuring quadriceps femoris muscle thickness.

Eur J Phys Rehabil Med. 2022-10

引用本文的文献

[1]
Is there a place for ultrasound in diagnosing sarcopenia?

Radiol Oncol. 2025-6-16

[2]
Normative data of ultrasound quadriceps rectus femoris geometric values. The ECOSARC-2 Study.

J Nutr Health Aging. 2025-8

[3]
Examiner experience moderates reliability of human lower extremity muscle ultrasound measurement - a double blinded measurement error study.

Ultrasound J. 2025-3-26

[4]
Effects of repeated use of post-exercise infrared sauna on neuromuscular performance and muscle hypertrophy.

Front Sports Act Living. 2025-3-4

[5]
Stressing the Relevance of Differentiating between Systematic and Random Measurement Errors in Ultrasound Muscle Thickness Diagnostics.

Sports Med Open. 2024-8-15

[6]
Muscle structure predictors of vertical jump performance in elite male volleyball players: a cross-sectional study based on ultrasonography.

Front Physiol. 2024-7-30

[7]
Reliability of assessing skeletal muscle architecture and tissue organization of the gastrocnemius medialis and vastus lateralis muscle using ultrasound and spatial frequency analysis.

Front Sports Act Living. 2024-1-18

[8]
Centile reference curves of the ultrasound-based characteristics of the rectus femoris muscle composition in children at 4-11 years old.

Front Pediatr. 2023-8-10

[9]
Physiology of Stretch-Mediated Hypertrophy and Strength Increases: A Narrative Review.

Sports Med. 2023-11

[10]
Preliminary Study: Short-term Beneficial Effects of Thai Tok Sen Massage on Pain, Pressure Pain Threshold, and Upper Trapezius Muscle Thickness Among People with Shoulder Pain.

Int J Ther Massage Bodywork. 2023-3-1

本文引用的文献

[1]
Sarcopenia in COPD: a systematic review and meta-analysis.

Eur Respir Rev. 2019-11-13

[2]
Validity of Ultrasound Imaging Versus Magnetic Resonance Imaging for Measuring Anterior Thigh Muscle, Subcutaneous Fat, and Fascia Thickness.

Methods Protoc. 2019-7-10

[3]
Assessing sarcopenia with vastus lateralis muscle ultrasound: an operative protocol.

Aging Clin Exp Res. 2018-4-26

[4]
The reliability and validity of ultrasound to quantify muscles in older adults: a systematic review.

J Cachexia Sarcopenia Muscle. 2017-7-12

[5]
Muscle Ultrasound and Sarcopenia in Older Individuals: A Clinical Perspective.

J Am Med Dir Assoc. 2017-2-13

[6]
Measurement of muscle mass in sarcopenia: from imaging to biochemical markers.

Aging Clin Exp Res. 2017-2

[7]
A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.

J Chiropr Med. 2016-6

[8]
Ultrasound-Based Detection of Low Muscle Mass for Diagnosis of Sarcopenia in Older Adults.

PM R. 2016-5

[9]
Frailty in heart failure.

Curr Heart Fail Rep. 2014-9

[10]
Validity of measuring distal vastus medialis muscle using rehabilitative ultrasound imaging versus magnetic resonance imaging.

Man Ther. 2014-6

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索