J Rehabil Med. 2021 Jul 6;53(7):jrm00212. doi: 10.2340/16501977-2854.
OBJECTIVE: To evaluate the reliability and validity of a standardized ultrasound examination protocol for measuring vastus lateralis muscle size. DESIGN: Prospective cohort study. SUBJECTS: Sixteen staff members of the university hospital of Heidelberg. METHODS: Muscle thickness, cross-sectional area and subcutaneous adipose tissue thickness were measured at 3 standardized sites on the right and left vastus lateralis muscle. Ultrasound measurements were collected by 2 independent investigators on 2 different days and compared with magnetic resonance imaging measurements. RESULTS: Intraclass correlation coefficients (ICC) for intra- and inter-rater reliability showed very good closeness of agreement for all parameters (ICC = 0.929-0.994, p < 0.001). Muscle thickness and subcutaneous adipose tissue thickness ultrasound and magnetic resonance imaging measurements revealed good to very good closeness of agreement (ICC = 0.835-0.969, p < 0.001), whereas cross-sectional area showed only average closeness of agreement (ICC = 0.727, p < 0.001). A strong predictive positive correlation for ultrasound and magnetic resonance imaging-based measurements of cross-sectional area was found (R² = 0.793, p < 0.001). CONCLUSION: By standardization of an examination protocol, quantitative vastus lateralis muscle ultrasound proved to be a reliable method for assessing vastus lateralis muscle size. Furthermore, this protocol is valid for measuring muscle thickness and subcutaneous adipose tissue thickness, although there seems to be a systematic underestimation of cross-sectional area depending on subcutaneous adipose tissue thickness.
目的:评估一种标准化超声检查方案测量股外侧肌大小的可靠性和有效性。
设计:前瞻性队列研究。
受试者:海德堡大学医院的 16 名工作人员。
方法:在股外侧肌的 3 个标准化部位测量肌肉厚度、横截面积和皮下脂肪组织厚度。由 2 名独立的调查员在 2 天内收集超声测量值,并与磁共振成像测量值进行比较。
结果:所有参数的组内和组间可靠性的内类相关系数(ICC)均显示出非常好的一致性(ICC=0.929-0.994,p<0.001)。肌肉厚度和皮下脂肪组织厚度的超声和磁共振成像测量值显示出良好到非常好的一致性(ICC=0.835-0.969,p<0.001),而横截面积仅显示出平均一致性(ICC=0.727,p<0.001)。超声和磁共振成像测量的横截面积之间存在很强的正预测相关性(R²=0.793,p<0.001)。
结论:通过检查方案的标准化,定量股外侧肌超声被证明是一种可靠的方法,可用于评估股外侧肌大小。此外,该方案对于测量肌肉厚度和皮下脂肪组织厚度是有效的,尽管根据皮下脂肪组织厚度,横截面积似乎存在系统低估。
Appl Physiol Nutr Metab. 2020-7
Eur J Phys Rehabil Med. 2022-10
Radiol Oncol. 2025-6-16
J Nutr Health Aging. 2025-8
Front Sports Act Living. 2025-3-4
Eur Respir Rev. 2019-11-13
Aging Clin Exp Res. 2018-4-26
J Cachexia Sarcopenia Muscle. 2017-7-12
J Am Med Dir Assoc. 2017-2-13
Aging Clin Exp Res. 2017-2
Curr Heart Fail Rep. 2014-9