乳腺病变评估及最终 BI-RADS 分类在放射状与蜿蜒状乳腺超声中的一致性。

Agreement in breast lesion assessment and final BI-RADS classification between radial and meander-like breast ultrasound.

机构信息

Department of Obstetrics and Gynecology, University Hospital Basel, Spitalstrasse 21, 4056, Basel, Switzerland.

Department of Clinical Research, Statistics and Data Management, University Basel, Schanzenstrasse 55, 4031, Basel, Switzerland.

出版信息

BMC Med Imaging. 2021 Jun 22;21(1):104. doi: 10.1186/s12880-021-00632-1.

Abstract

BACKGROUND

This study prospectively investigates the agreement between radial (r-US) and meander-like (m-US) breast ultrasound with regard to lesion location, lesion size, morphological characteristics and final BI-RADS classification of individual breast lesions.

METHODS

Each patient of a consecutive, unselected, mixed collective received a dual ultrasound examination.

RESULTS

The agreement between r-US and m-US for lesion location ranged from good (lesion to mammilla distance ICC 0.64; lesion to skin distance ICC 0.72) to substantial (clock-face localization κ 0.70). For lesion size the agreement was good (diameter ICC 0.72; volume ICC 0.69), for lesion margin and architectural distortion it was substantial (κ 0.68 and 0.70, respectively). Most importantly, there was a substantial agreement (κ 0.76) in the final BI-RADS classification between r-US and m-US.

CONCLUSIONS

Our recent comparison of radial and meander-like breast US revealed that the diagnostic accuracy of the two scanning methods was comparable. In this study, we observe a high degree of agreement between m-US and r-US for the lesion description (location, size, morphology) and final BI-RADS classification. These findings corroborate that r-US is a suitable alternative to m-US in daily clinical practice. Trial registration NCT02358837. Registered January 2015, retrospectively registered https://clinicaltrials.gov/ct2/results?cond=&term=NCT02358837&cntry=&state=&city=&dist =.

摘要

背景

本研究前瞻性地评估了放射状(r-US)和蜿蜒状(m-US)乳腺超声在个体乳腺病变的位置、病变大小、形态特征和最终 BI-RADS 分类方面的一致性。

方法

连续选择的混合队列中的每位患者均接受了双超声检查。

结果

r-US 和 m-US 之间的病变位置的一致性从良好(病变至乳头的距离 ICC 为 0.64;病变至皮肤的距离 ICC 为 0.72)到实质性(时钟面定位 κ 值为 0.70)。病变大小的一致性为良好(直径 ICC 为 0.72;体积 ICC 为 0.69),病变边缘和结构扭曲的一致性为实质性(κ 值分别为 0.68 和 0.70)。最重要的是,r-US 和 m-US 之间的最终 BI-RADS 分类存在实质性的一致性(κ 值为 0.76)。

结论

我们最近对放射状和蜿蜒状乳腺 US 的比较表明,两种扫描方法的诊断准确性相当。在这项研究中,我们观察到 m-US 和 r-US 在病变描述(位置、大小、形态)和最终 BI-RADS 分类方面具有高度的一致性。这些发现证实 r-US 是日常临床实践中 m-US 的合适替代方法。试验注册 NCT02358837。于 2015 年 1 月注册,回顾性注册 https://clinicaltrials.gov/ct2/results?cond=&term=NCT02358837&cntry=&state=&city=&dist=。