Dan Med J. 2021 Jun 14;68(7):A03210217.
Fast and accurate detection of SARS-CoV-2 is essential in limiting the COVID-19 pandemic. Rapid antigen (AG) tests provide results within minutes; however, their accuracy has been questioned. The study aims to determine the accuracy and cost of the STANDARD Q COVID-19 AG test compared with RT-PCR.
Individuals 18 years or older with an appointment for a RT-PCR test on 26-31 December 2020 at a public test centre in Copenhagen, Denmark were invited to participate. An oropharyngeal swab was collected for RT-PCR analysis, followed by a nasopharyngeal swab examined by the AG test (SD Biosensor). The diagnostic accuracy of the AG test was calculated with RT-PCR as reference. Costs were evaluated for both tests.
A total of 4,811 paired conclusive test results were collected (median age: 45 years, female: 53%). The RT-PCR test revealed 221 (4.6%) positive tests. The overall sensitivity and specificity of the AG test were 69.7% and 99.5%, respectively. Viral cycle threshold values were significantly higher in individuals with false negative AG tests than in individuals who were true positives. The RT-PCR test and AG test costs were 67.0 DKK (10.8 USD) and 35.0 DKK (5.7 USD), respectively, per positive case detected at 100,000 daily tests.
The AG test enables mass testing and provides immediate results, which is important in SARS-CoV-2 screening. The AG test is a good and relevant supplement to RT-PCR testing in public SARS-CoV-2 screenings.
This project received no external funding. Copenhagen Medical A/S delivering the rapid AG tests and provided test personnel but were not otherwise involved.
Clinicaltrials.org: NCT04716088.
快速准确地检测 SARS-CoV-2 对于限制 COVID-19 大流行至关重要。快速抗原(AG)检测可在数分钟内提供结果;然而,其准确性受到了质疑。本研究旨在比较 STANDARD Q COVID-19 AG 检测与 RT-PCR 的准确性和成本。
邀请 2020 年 12 月 26 日至 31 日在丹麦哥本哈根的一个公共检测中心预约进行 RT-PCR 检测的 18 岁或以上的个体参加。采集口咽拭子进行 RT-PCR 分析,然后用 AG 检测(SD Biosensor)检测鼻咽拭子。AG 检测的诊断准确性以 RT-PCR 为参考进行计算。评估了两种检测的成本。
共收集了 4811 对明确的检测结果(中位年龄:45 岁,女性:53%)。RT-PCR 检测显示 221 例(4.6%)阳性检测。AG 检测的总体敏感性和特异性分别为 69.7%和 99.5%。假阴性 AG 检测个体的病毒循环阈值明显高于真阳性个体。每检测 10 万例阳性病例,RT-PCR 检测和 AG 检测的成本分别为 67.0 DKK(10.8 美元)和 35.0 DKK(5.7 美元)。
AG 检测可进行大规模检测并提供即时结果,这对于 SARS-CoV-2 筛查很重要。AG 检测是公共 SARS-CoV-2 筛查中 RT-PCR 检测的良好且相关的补充。
本项目没有外部资金支持。提供快速 AG 检测的哥本哈根医疗 A/S 提供了检测人员,但没有参与其他方面。
Clinicaltrials.org:NCT04716088。