Department of Spine and Osteopathy Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, China.
Department of Spine Surgery, The People's Hospital of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China.
J Int Med Res. 2021 Jun;49(6):3000605211020219. doi: 10.1177/03000605211020219.
The purpose of this study was to examine the biomechanical effects of fixation on range of motion (ROM) in the upper and lower adjacent segments of different lumbar spine segments in a goat spine model.
Fifteen goat spine specimens (vertebrae T12-S1) were randomly divided into three groups: A (single-segment fixation), B (double-segment fixation), and C (triple-segment fixation). Motion in different directions was tested using a spinal motion simulation test system with five external loading forces. Transverse, forward-backward, and vertical displacement of the upper and lower adjacent segments were measured.
As the external load increased, the upper and lower adjacent segment ROM increased. A significantly greater ROM in group C compared with group A was found when the applied external force was greater than 75 N. The upper adjacent segment showed a significantly greater ROM than the lower adjacent segment ROM within each group.
Adjacent segment ROM increased with an increasing number of fixed lumbar segments. The upper adjacent segment ROM was greater than that of the lower adjacent segments. Adjacent segment stability after lumbar internal fixation worsened with an increasing number of fixed segments.
本研究旨在探讨羊脊柱模型中不同腰椎节段固定对上下相邻节段活动范围(ROM)的生物力学影响。
将 15 个羊脊柱标本(T12-S1 椎体)随机分为三组:A 组(单节段固定)、B 组(双节段固定)和 C 组(三节段固定)。使用脊柱运动模拟测试系统和五个外部加载力来测试不同方向的运动。测量上下相邻节段的横向、前后和垂直位移。
随着外部负载的增加,上下相邻节段的 ROM 增加。当施加的外力大于 75N 时,与 A 组相比,C 组的 ROM 显著增加。在每组内,上相邻节段的 ROM 明显大于下相邻节段的 ROM。
随着固定腰椎节段数量的增加,相邻节段的 ROM 增加。上相邻节段的 ROM 大于下相邻节段的 ROM。随着固定节段数量的增加,腰椎内固定后相邻节段的稳定性变差。