Correlation Analysis of Different Measurement Places of Galvanic Skin Response in Test Groups Facing Pleasant and Unpleasant Stimuli.

机构信息

Department of Productivity and Innovation, Universidad de la Costa, 080 002 Barranquilla, Colombia.

Department of Computer Science, Electrical and Space Engineering, Luleå Tekniska Universitet, 971 87 Luleå, Sweden.

出版信息

Sensors (Basel). 2021 Jun 19;21(12):4210. doi: 10.3390/s21124210.

Abstract

The galvanic skin response (GSR; also widely known as electrodermal activity (EDA)) is a signal for stress-related studies. Given the sparsity of studies related to the GSR and the variety of devices, this study was conducted at the Human Health Activity Laboratory (H2AL) with 17 healthy subjects to determine the variability in the detection of changes in the galvanic skin response among a test group with heterogeneous respondents facing pleasant and unpleasant stimuli, correlating the GSR biosignals measured from different body sites. We experimented with the right and left wrist, left fingers, the inner side of the right foot using Shimmer3GSR and Empatica E4 sensors. The results indicated the most promising homogeneous places for measuring the GSR, namely, the left fingers and right foot. The results also suggested that due to a significantly strong correlation among the inner side of the right foot and the left fingers, as well as the moderate correlations with the right and left wrists, the foot may be a suitable place to homogenously measure a GSR signal in a test group. We also discuss some possible causes of weak and negative correlations from anomalies detected in the raw data possibly related to the sensors or the test group, which may be considered to develop robust emotion detection systems based on GRS biosignals.

摘要

皮肤电反应(GSR;也被广泛称为皮肤电活动(EDA))是与应激相关研究的信号。鉴于与 GSR 相关的研究稀缺以及设备种类繁多,本研究在人类健康活动实验室(H2AL)进行,共有 17 名健康受试者参与,旨在确定面对愉快和不愉快刺激的异质应答者测试组中皮肤电反应变化检测的可变性,并将来自不同身体部位的 GSR 生物信号进行相关联。我们使用 Shimmer3GSR 和 Empatica E4 传感器分别在右手腕、左手腕、左手手指和右脚内测进行了实验。结果表明,测量 GSR 最有前途的同质部位是左手手指和右脚。结果还表明,由于右脚内测和左手手指之间具有非常强的相关性,以及与右手腕和左手腕之间的中度相关性,因此脚部可能是测试组中均匀测量 GSR 信号的合适部位。我们还讨论了原始数据中异常检测可能导致的弱相关性和负相关性的一些可能原因,这些原因可能与传感器或测试组有关,这可能有助于开发基于 GRS 生物信号的稳健情绪检测系统。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a82e/8234095/d9ffe05ec1c2/sensors-21-04210-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验