健康肺脏的区域通气分布:能否为电阻抗断层扫描参数建立参考值?

Regional ventilation distribution in healthy lungs: can reference values be established for electrical impedance tomography parameters?

作者信息

Yang Lin, Dai Meng, Cao Xinsheng, Möller Knut, Dargvainis Mantas, Frerichs Inéz, Becher Tobias, Fu Feng, Zhao Zhanqi

机构信息

Department of Aerospace Medicine, Fourth Military Medical University, Xi'an, China.

Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.

出版信息

Ann Transl Med. 2021 May;9(9):789. doi: 10.21037/atm-20-7442.

Abstract

BACKGROUND

Although electrical impedance tomography (EIT) is widely used for monitoring regional ventilation distribution, reference values have yet to be established for clinical use. The present study aimed to evaluate the feasibility of creating reference values for standard EIT parameters for potential clinical application.

METHODS

A total of 75 participants with healthy lungs were included in this prospective study (male:female, 48:27; age, 34±14 years; height, 172±7 cm; weight, 73±12 kg). The subjects were examined during spontaneous breathing in the supine position. EIT measurements were performed at the level of the 4 intercostal space. Commonly used EIT-based parameters, including the center of ventilation (CoV), dorsal and most dorsal fractions of ventilation distribution (TV and TV respectively), global inhomogeneity (GI) index, and standard deviation of regional ventilation delay index (RVD) were calculated.

RESULTS

Following outlier detection, EIT data from 71 subjects were finally evaluated. The values of the evaluated parameters were: CoV, 48.7%±1.7%; TVD, 48.1%±5.4%; TV, 7.1%±1.8%; GI, 0.49±0.04; and RVD, 7.0±2.0. The coefficients of variation for CoV and GI were low (0.03 and 0.07, respectively), but those for TV and RVD were comparatively high (0.26 and 0.28, respectively). None of the evaluated parameters showed a significant correlation with age. The GI index showed a weak but significant correlation with body mass index (R=0.29, P=0.01). The RVD was slightly higher in males than in females.

CONCLUSIONS

Our study indicated that CoV and GI were stable parameters with small coefficients of variation in participants with healthy lungs. The creation of EIT parameter reference values for setting treatment targets may be feasible.

摘要

背景

尽管电阻抗断层成像(EIT)被广泛用于监测局部通气分布,但尚未建立可用于临床的参考值。本研究旨在评估为标准EIT参数创建参考值以用于潜在临床应用的可行性。

方法

本前瞻性研究共纳入75名肺部健康的参与者(男性:女性,48:27;年龄,34±14岁;身高,172±7厘米;体重,73±12千克)。受试者在仰卧位自主呼吸时接受检查。在第4肋间水平进行EIT测量。计算常用的基于EIT的参数,包括通气中心(CoV)、通气分布的背侧和最背侧分数(分别为TVD和TV)、全局不均匀性(GI)指数以及区域通气延迟指数(RVD)的标准差。

结果

经过异常值检测后,最终评估了71名受试者的EIT数据。评估参数的值为:CoV,48.7%±1.7%;TVD,48.1%±5.4%;TV,7.1%±1.8%;GI,0.49±0.04;RVD,7.0±2.0。CoV和GI的变异系数较低(分别为0.03和0.07),但TV和RVD的变异系数相对较高(分别为0.26和0.28)。所有评估参数均与年龄无显著相关性。GI指数与体重指数呈弱但显著的相关性(R = 0.29,P = 0.01)。男性的RVD略高于女性。

结论

我们的研究表明,CoV和GI是肺部健康参与者中变异系数较小的稳定参数。为设定治疗目标创建EIT参数参考值可能是可行的。