Tsai W C, Chu S H, Lee S Y, Lee P F
Department of Microbiology and Immunology, National Yang-Ming Medical College, Taipei, ROC.
Zhonghua Min Guo Wei Sheng Wu Ji Mian Yi Xue Za Zhi. 1987 Aug;20(3):257-61.
Aeromonas hydrophila has been reported to be involved in the opportunistic infection of human beings, therefore, its rapid diagnosis from the clinical specimens was considered to be extremely important for the prognosis. The effect of different brands of MacConkey (MAC) and xylose lysine deoxycholate (XLD) agars on the plating efficiency and colony size of A. hydrophila was evaluated by comparing with blood agar. Results indicate that (i) except Eiken's MAC have low plating efficiency, all the MAC from BBL, Difco, Mast, Merck, and Gibco have good plating efficiency; (ii) except Eiken's and Gibco XLD, all XLD from Difco, Mast, and Merck have larger bacterial colony size; and (iii) colonies of A. hydrophila appeared on MAC are larger than those on XLD of the same brands. We suggested that a clinical laboratory microbiologist should be alert in selecting the appropriate media to isolate the clinically important bacteria.
据报道,嗜水气单胞菌可引发人类机会性感染,因此,从临床标本中快速诊断该菌对预后极为重要。通过与血琼脂比较,评估了不同品牌的麦康凯(MAC)琼脂和木糖赖氨酸脱氧胆酸盐(XLD)琼脂对嗜水气单胞菌平板接种效率和菌落大小的影响。结果表明:(i)除荣研公司的MAC平板接种效率较低外,BBL、Difco、Mast、默克和Gibco公司的所有MAC平板接种效率良好;(ii)除荣研公司和Gibco公司的XLD外,Difco、Mast和默克公司的所有XLD菌落尺寸更大;(iii)同一品牌的MAC上出现的嗜水气单胞菌菌落比XLD上的菌落大。我们建议临床实验室微生物学家在选择合适的培养基以分离临床重要细菌时应保持警惕。