[猪二尖瓣功能障碍的多普勒评估]

[Doppler evaluation of porcine mitral valve dysfunction].

作者信息

Nakamura K, Matsumura K, Satomi G, Sakai K, Ishizuka N, Mori K, Shiina T, Kikuchi N, Hirosawa K, Takao A

机构信息

Department of Medical Cardiology, Tokyo Women's Medical College.

出版信息

J Cardiogr. 1986 Dec;16(4):929-39.

PMID:3429909
Abstract

Seventy patients with bioprosthetic mitral valve were examined to study the applicability of the Doppler techniques including pulsed, continuous wave and color Doppler echocardiography in diagnosing and evaluating the severity of prosthetic valve dysfunction. The study population consisted of 70 patients who underwent mitral valve replacement (45 patients with Hancock valve, 13 with Angell-Shiley valve, 10 with Carpentier-Edwards valve). The dysfunctions were transvalvular regurgitation in 20 instances and paravalvular regurgitation in three, all of which were confirmed at surgery. A control group of 47 patients with the normally functioning porcine prosthetic mitral valve were also studied. Diastolic transmitral flow patterns were recorded from parasternal and apical approaches using color Doppler echocardiography, and the direction of the flow was definitely identified on the flow image. Transmitral flow signals spread from the mitral orifice to the mid-portion of the interventricular septum, and its direction was perpendicular toward the mitral ring in all cases. Flow velocity patterns in the left ventricle and atrium were recorded in the apical long-axis view of the left ventricle or apical four-chamber view using pulsed (high pulse repetition frequency) and continuous wave Doppler techniques. Two dynamic alterations in patients with the porcine mitral valve were evaluated from 1) the peak velocity and pressure half time (PHT) of transmitral flow in early diastole, and 2) the regurgitant jet in the left atrium indicating transvalvular or paravalvular regurgitation. The results were as follows: 1. Normally functioning porcine mitral valves were characterized by peak velocities (PV) less than or equal to 1.82 (mean +/- SD 1.44 +/- 0.27) m/sec and PHT less than or equal to 180 (mean +/- SD: 135 +/- 30) msec. In 23 patients with prosthetic valve dysfunction documented at surgery, peak velocity (mean +/- SD 2.23 +/- 0.19 m/sec) was significantly greater (p less than .001) than that of patients in the normally functioning prosthetic valves, and PHT ranged from 135 to 340 msec (mean +/- SD: 226 +/- 81 msec). 2. Among the 23 patients with porcine valve dysfunction, a harmonic striped pattern were recorded at the mitral valve levels in eight patients. All these patients had a musical murmur, and their peak velocity was more than 2.0 m/sec, but the PHT was less than 180 msec in seven patients. In these patients, valvular tears without calcification were confirmed at surgery.(ABSTRACT TRUNCATED AT 400 WORDS)

摘要

对70例生物瓣二尖瓣患者进行检查,以研究脉冲、连续波和彩色多普勒超声心动图等多普勒技术在诊断和评估人工瓣膜功能障碍严重程度方面的适用性。研究对象包括70例接受二尖瓣置换术的患者(45例使用Hancock瓣,13例使用Angell-Shiley瓣,10例使用Carpentier-Edwards瓣)。其中20例为瓣周反流,3例为瓣环旁反流,所有这些在手术中均得到证实。还对47例人工猪二尖瓣功能正常的患者组成的对照组进行了研究。使用彩色多普勒超声心动图从胸骨旁和心尖途径记录舒张期二尖瓣血流模式,并在血流图像上明确血流方向。二尖瓣血流信号从二尖瓣口扩散至室间隔中部,在所有病例中其方向均垂直于二尖瓣环。使用脉冲(高脉冲重复频率)和连续波多普勒技术在左心室心尖长轴视图或心尖四腔视图中记录左心室和心房的血流速度模式。从以下两方面评估人工猪二尖瓣患者的两种动态改变:1)舒张早期二尖瓣血流的峰值速度和压力减半时间(PHT);2)左心房内提示瓣周或瓣环旁反流的反流束。结果如下:1. 人工猪二尖瓣功能正常的特征为峰值速度(PV)小于或等于1.82(均值±标准差1.44±0.27)m/sec,PHT小于或等于180(均值±标准差:135±30)msec。在手术中记录有瓣膜功能障碍的23例患者中,峰值速度(均值±标准差2.23±0.19 m/sec)显著高于(p<0.001)人工瓣膜功能正常的患者,PHT范围为135至340 msec(均值±标准差:226±81 msec)。2. 在23例人工猪瓣膜功能障碍患者中,8例在二尖瓣水平记录到谐波条纹模式。所有这些患者均有音乐样杂音,其峰值速度大于2.0 m/sec,但7例患者的PHT小于180 msec。在这些患者中,手术证实为无钙化的瓣膜撕裂。(摘要截于400字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验