Sun Guoxi, Cao Lei, Zhang Haiying
Department of Stomatology, Jiaozhou Central Hospital of Qingdao Qingdao, Shandong Province, China.
Department of Stomatology, Qingdao Stomatological Hospital Qingdao, Shandong Province, China.
Am J Transl Res. 2021 Jun 15;13(6):7221-7227. eCollection 2021.
We aimed to investigate the effect of locking-taper implants on restoration in the posterior teeth area with insufficient occlusal-gingival distances.
Forty-five patients undergoing dental implants in our hospital with occlusal-gingival distances under 5 mm in the posterior teeth area were recruited for this retrospective study. A total of 78 locking-taper implants were implanted in these patients. The patients were followed up for two years to observe the implant retention rate, the implant bone heights at different time points after the restoration, and the effects of the different implant placement depths on the marginal bone mass at the implants. Meanwhile, we evaluated the peri-implant soft tissue status by measuring the modified plaque index, the gingival index, and probing the depths. The postoperative complications and the patient satisfaction levels were also analyzed.
During the 2-year follow-up, the patients' implant retention rate was 100.00%. The implant placement depths did not affect the marginal bone masses at the implants at T0-T1 or T1-T2 (T0: the day after the restoration, T1: at one year after the restoration, T2: at two years after the restoration, all P>0.05). The peri-implant soft tissues in most of the patients were in good condition, and only a few patients had a small amount of plaque or slight gingival swelling. The average probe depth was 3.23±1.20 mm during the follow-up. Only one patient had abutment loosening, and one had a dental prosthesis fall off. The patients did not feel any numbness, continuous pain, or other abnormalities during the follow-up, and the overall patient satisfaction rate was over 97.78%.
Locking-taper implants can achieve good clinical outcomes in the restoration of the posterior area with insufficient occlusal-gingival distances. The implants can achieve a high implant retention rate, have no adverse effects on the peri-implant soft tissues, have a low complication rate, cause no significant marginal bone mass loss at the implants, and have a high patient satisfaction rate.
我们旨在研究锁定锥形种植体对咬合龈距离不足的后牙区修复的影响。
本回顾性研究纳入了我院45例在后牙区咬合龈距离小于5mm且接受牙种植的患者。共为这些患者植入78枚锁定锥形种植体。对患者进行两年随访,观察种植体留存率、修复后不同时间点的种植体骨高度,以及不同种植体植入深度对种植体边缘骨量的影响。同时,通过测量改良菌斑指数、牙龈指数和探查深度来评估种植体周围软组织状况。还分析了术后并发症及患者满意度。
在2年随访期间,患者的种植体留存率为100.00%。种植体植入深度在T0 - T1或T1 - T2时(T0:修复后第1天,T1:修复后1年,T2:修复后2年)对种植体边缘骨量无影响(所有P>0.05)。大多数患者的种植体周围软组织状况良好,仅有少数患者有少量菌斑或轻微牙龈肿胀。随访期间平均探查深度为3.23±1.20mm。仅有1例患者基台松动,1例患者义齿脱落。随访期间患者未感到任何麻木、持续性疼痛或其他异常,总体患者满意度超过97.78%。
锁定锥形种植体在咬合龈距离不足的后牙区修复中可取得良好的临床效果。该种植体能实现较高的种植体留存率,对种植体周围软组织无不良影响,并发症发生率低,种植体边缘骨量无明显丢失,患者满意度高。