Suppr超能文献

基于 X 射线的实时图像引导在心脏放射性消融术中的验证概念。

Proof-of-concept for x-ray based real-time image guidance during cardiac radioablation.

机构信息

ACRF Image X Institute, University of Sydney, Sydney, Australia.

Ingham Institute for Applied Medical Research, Liverpool, Australia.

出版信息

Phys Med Biol. 2021 Aug 24;66(17). doi: 10.1088/1361-6560/ac1834.

Abstract

Cardiac radioablation offers non-invasive treatments for refractory arrhythmias. However, treatment delivery for this technique remains challenging. In this paper, we introduce the first method for real-time image guidance during cardiac radioablation for refractory atrial fibrillation on a standard linear accelerator. Our proposed method utilizes direct diaphragm tracking on intrafraction images to estimate the respiratory component of cardiac substructure motion. We compare this method to treatment scenarios without real-time image guidance using the 4D-XCAT digital phantom. Pre-treatment and intrafraction imaging was simulated for 8 phantoms with unique anatomies programmed using cardiorespiratory motion from healthy volunteers. As every voxel in the 4D-XCAT phantom is labelled precisely according to the corresponding anatomical structure, this provided ground-truth for quantitative evaluation. Tracking performance was compared to the ground-truth for simulations with and without real-time image guidance using the left atrium as an exemplar target. Differences in target volume size, mean volumetric coverage, minimum volumetric coverage and geometric error were recorded for each simulation. We observed that differences in target volume size were statistically significant ( < 0.001) across treatment scenarios and that real-time image guidance enabled reductions in target volume size ranging from 11% to 24%. Differences in mean and minimum volumetric coverage were statistically insignificant (both = 0.35) while differences in geometric error were statistically significant ( = 0.039). The results of this study provide proof-of-concept for x-ray based real-time image guidance during cardiac radioablation.

摘要

心脏放射性消融术为难治性心律失常提供了非侵入性治疗。然而,这种技术的治疗输送仍然具有挑战性。在本文中,我们介绍了在标准线性加速器上进行难治性心房颤动心脏放射性消融时实时图像引导的第一种方法。我们提出的方法利用分次内图像上的直接膈膜跟踪来估计心脏亚结构运动的呼吸分量。我们将这种方法与没有实时图像引导的治疗方案进行了比较,使用了 4D-XCAT 数字体模。对 8 个具有独特解剖结构的体模进行了预治疗和分次内成像模拟,这些解剖结构是使用健康志愿者的心呼吸运动编程的。由于 4D-XCAT 体模中的每个体素都根据相应的解剖结构进行了精确标记,因此为定量评估提供了真实依据。使用左心房作为示例目标,比较了跟踪性能与具有和不具有实时图像引导的模拟的真实依据。记录了每种模拟的目标体积大小、平均体积覆盖率、最小体积覆盖率和几何误差的差异。我们观察到,在治疗方案中,目标体积大小的差异具有统计学意义(均<0.001),实时图像引导可使目标体积大小减少 11%至 24%。平均和最小体积覆盖率的差异无统计学意义(均=0.35),而几何误差的差异具有统计学意义(=0.039)。本研究的结果为心脏放射性消融过程中的基于 X 射线的实时图像引导提供了概念验证。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/af8c/8815757/b8211cd68029/nihms-1747254-f0001.jpg

相似文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验