INTRODUCTION

The aim of this study was to evaluate and compare the effects of class II fixed functional treatment with a cast splint Herbst appliance (HA; Herbst Set I, Dentaurum, Ispringen, Germany) and Forsus fatigue resistant device (FRD; 3M Unitek Corp., Monrovia, CA, USA) on external apical root resorption (EARR) in posterior teeth.

METHODS

In all, 40 patients (15 male and 25 female) with class II division 1 malocclusion were treated with two fixed functional appliances: HA (20 patients, mean age 14.60 ± 1.14 years) and FRD (20 patients, mean age 14.15 ± 1.28 years). The vestibular lengths of the first molars and premolars were measured on panoramic radiographs and converted to actual tooth length using the magnification coefficient (MC), which was calculated using dental models. Intragroup comparisons of pre- and posttreatment tooth lengths were performed with the paired t‑test and Wilcoxon signed-rank test, while intergroup comparisons were performed with the Mann-Whitney U test.

RESULTS

Pretreatment tooth length values decreased significantly with HA and FRD therapies for all posterior teeth. The maximum resorption was observed in the mandibular first premolar with a mean of 0.81 mm following HA and 1.55 mm following FRD treatment. While no significant difference existed between the EARR values of the HA and FRD groups for maxillary teeth, the amount of EARR of mandibular posterior teeth in the FRD group was significantly higher than in the HA group.

CONCLUSIONS

In patients treated with HA or FRD, the tooth length of posterior teeth decreased to a clinically minor but statistically significant degree. The root resorption effect of FRD therapy in mandibular posterior teeth was significantly higher than that of HA therapy.

摘要

引言

本研究的目的是评估和比较II类固定功能矫治器(带铸造夹板的Herbst矫治器(HA;Herbst Set I,德国登特伦公司,伊斯普林根))和Forsus抗疲劳矫治器(FRD;美国3M Unitek公司,加利福尼亚州蒙罗维亚)对后牙根尖外吸收(EARR)的影响。

方法

总共40例II类1分类错牙合患者(15例男性和25例女性)接受两种固定功能矫治器治疗:HA(20例患者,平均年龄14.60±1.14岁)和FRD(20例患者,平均年龄14.15±1.28岁)。在全景X线片上测量第一磨牙和前磨牙的前庭长度,并使用放大系数(MC)将其转换为实际牙长,放大系数通过牙模计算得出。治疗前后牙长的组内比较采用配对t检验和Wilcoxon符号秩检验,组间比较采用Mann-Whitney U检验。

结果

对于所有后牙,HA和FRD治疗后治疗前牙长值均显著降低。在下颌第一前磨牙中观察到最大吸收,HA治疗后平均为0.81mm,FRD治疗后为1.55mm。虽然HA组和FRD组上颌牙的EARR值之间没有显著差异,但FRD组下颌后牙的EARR量显著高于HA组。

结论

在接受HA或FRD治疗的患者中,后牙牙长减少到临床上较小但具有统计学意义的程度。FRD治疗在下颌后牙的牙根吸收效应显著高于HA治疗。