Suppr超能文献

一项应用于男性军事机组人员 G 耐力试验和监测的心脏力量指数。

A Cardiac Force Index Applied to the G Tolerance Test and Surveillance among Male Military Aircrew.

机构信息

Aviation Physiology Research Laboratory, Kaohsiung Armed Forces General Hospital Gangshan Branch, Kaohsiung City 820, Taiwan.

School of Public Health, National Defense Medical Center, Taipei City 114, Taiwan.

出版信息

Int J Environ Res Public Health. 2021 Aug 21;18(16):8832. doi: 10.3390/ijerph18168832.

Abstract

Military aircrew are occupationally exposed to a high-G environment. A tolerance test and surveillance is necessary for military aircrew before flight training. A cardiac force index (CFI) has been developed to assess long-distance running by health technology. We added the parameter CFI to the G tolerance test and elucidated the relationship between the CFI and G tolerance. A noninvasive device, BioHarness 3.0, was used to measure heart rate (HR) and activity while resting and walking on the ground. The formula for calculating cardiac function was CFI = weight × activity/HR. Cardiac force ratio (CFR) was calculated by walking CFI (WCFI)/resting CFI (RCFI). G tolerance included relaxed G tolerance (RGT) and straining G tolerance (SGT) tested in the centrifuge. Among 92 male participants, the average of RCFI, WCFI, and CFR were 0.02 ± 0.04, 0.15 ± 0.04, and 10.77 ± 4.11, respectively. Each 100-unit increase in the WCFI increased the RGT by 0.14 G and the SGT by 0.17 G. There was an increased chance of RGT values higher than 5 G and SGT values higher than 8 G according to the WCFI increase. Results suggested that WCFI is positively correlated with G tolerance and has the potential for G tolerance surveillance and programs of G tolerance improvement among male military aircrew.

摘要

军事机组人员在职业上暴露于高 G 环境中。在飞行训练前,对军事机组人员进行耐高 G 能力测试和监测是必要的。心脏力量指数(CFI)已被开发用于通过健康技术评估长跑。我们将 CFI 参数添加到耐高 G 测试中,并阐明了 CFI 与耐高 G 能力之间的关系。使用非侵入性设备 BioHarness 3.0 来测量静息和在地面行走时的心率(HR)和活动。计算心脏功能的公式为 CFI = 体重×活动/HR。通过行走 CFI(WCFI)/静息 CFI(RCFI)计算心脏力量比(CFR)。G 耐受能力包括在离心机中测试的放松 G 耐受能力(RGT)和紧张 G 耐受能力(SGT)。在 92 名男性参与者中,RCFI、WCFI 和 CFR 的平均值分别为 0.02±0.04、0.15±0.04 和 10.77±4.11。WCFI 每增加 100 个单位,RGT 增加 0.14 G,SGT 增加 0.17 G。根据 WCFI 的增加,RGT 值高于 5 G 和 SGT 值高于 8 G 的可能性增加。结果表明,WCFI 与 G 耐受能力呈正相关,具有在男性军事机组人员中进行 G 耐受能力监测和 G 耐受能力改善计划的潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/83b6/8391946/ddf946ed9b95/ijerph-18-08832-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验